{"id":23383,"date":"2024-11-12T12:44:40","date_gmt":"2024-11-12T12:44:40","guid":{"rendered":"https:\/\/www.metlaninst.com\/?p=23383"},"modified":"2025-07-12T13:49:37","modified_gmt":"2025-07-12T13:49:37","slug":"guia-de-seleccion-de-caudalimetros-electromagneticos","status":"publish","type":"post","link":"https:\/\/metlaninst.com\/es\/guia-de-seleccion-de-caudalimetros-electromagneticos\/","title":{"rendered":"Gu\u00eda de selecci\u00f3n de caudal\u00edmetros electromagn\u00e9ticos"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"23383\" class=\"elementor elementor-23383\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c79f7ff e-flex e-con-boxed e-con e-parent\" data-id=\"c79f7ff\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-62f4acef elementor-widget elementor-widget-text-editor\" data-id=\"62f4acef\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><p><a href=\"https:\/\/metlaninst.com\/es\/caudalimetros-magneticos\/\" target=\"_blank\" rel=\"noopener\">Caudal\u00edmetros electromagn\u00e9ticos<\/a> se utilizan ampliamente en aplicaciones industriales para la medici\u00f3n de caudal, especialmente en l\u00edquidos sin part\u00edculas s\u00f3lidas. Su precisi\u00f3n y fiabilidad son cruciales en muchas industrias. Seleccionar el caudal\u00edmetro electromagn\u00e9tico adecuado implica tener en cuenta varios factores relacionados con las condiciones de funcionamiento y las caracter\u00edsticas del medio medido. A continuaci\u00f3n se exponen una serie de consideraciones clave que le ayudar\u00e1n a seleccionar cient\u00edficamente el caudal\u00edmetro electromagn\u00e9tico m\u00e1s adecuado.<\/p>\n<p>\u00bfQuiere saber qu\u00e9 es y c\u00f3mo funciona un caudal\u00edmetro magn\u00e9tico? Aqu\u00ed tiene una completa gu\u00eda sobre <a href=\"https:\/\/metlaninst.com\/es\/caudalimetro-electromagnetico-y-principios-de-funcionamiento\/\" target=\"_blank\" rel=\"noopener\">caudal\u00edmetros magn\u00e9ticos<\/a>.<\/p><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3e4a446 e-flex e-con-boxed e-con e-parent\" data-id=\"3e4a446\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-05886d9 elementor-widget elementor-widget-heading\" data-id=\"05886d9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00cdndice<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-83991aa e-flex e-con-boxed e-con e-parent\" data-id=\"83991aa\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-186d349 elementor-widget elementor-widget-text-editor\" data-id=\"186d349\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"#1\">Comprender las caracter\u00edsticas del medio medido<\/a><\/li>\n<\/ul>\n<p><a href=\"#2\">1. Requisitos de conductividad<\/a><br \/><a href=\"#3\">2. Composici\u00f3n del medio y burbujas de gas<\/a><br \/><a href=\"#4\">3. Sedimentos e incrustaciones<\/a><br \/><a href=\"#5\">4.  Requisitos de higiene y calidad alimentaria<\/a><br \/><a href=\"#6\">5. Resistencia a la corrosi\u00f3n<\/a><\/p>\n<ul>\n<li><a href=\"#7\">Par\u00e1metros de funcionamiento<\/a><\/li>\n<\/ul>\n<p><a href=\"#7\">1. Temperatura y presi\u00f3n<\/a><br \/><a href=\"#8\">2. Coincidencia de di\u00e1metro de tuber\u00eda y rango de caudal<\/a><br \/><a href=\"#9\">3. Velocidad del flujo y flujo a escala completa<\/a><\/p>\n<ul>\n<li><a href=\"#10\">\u00a0Elegir el nivel de precisi\u00f3n adecuado<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-171e48a elementor-widget elementor-widget-text-editor\" data-id=\"171e48a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Related Posts:<\/p>\n<ul>\n<li><a href=\"https:\/\/metlaninst.com\/es\/todo-sobre-los-caudalimetros-de-lodos\/\">Todo sobre los caudal\u00edmetros de purines<\/a><\/li>\n<li><a href=\"https:\/\/metlaninst.com\/es\/como-elegir-caudalimetros-para-aguas-residuales\/\">C\u00f3mo elegir caudal\u00edmetros para aguas residuales<\/a><\/li>\n<li><a href=\"https:\/\/metlaninst.com\/es\/como-elegir-los-caudalimetros-de-agua\/\">How to Choose Water Flow Meters<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-acbfbc3 elementor-widget elementor-widget-menu-anchor\" data-id=\"acbfbc3\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"1\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d14e4f7 e-flex e-con-boxed e-con e-parent\" data-id=\"d14e4f7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9267545 elementor-widget elementor-widget-heading\" data-id=\"9267545\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comprender las caracter\u00edsticas del medio medido<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2ea2ab e-flex e-con-boxed e-con e-parent\" data-id=\"b2ea2ab\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d862a82 elementor-widget elementor-widget-text-editor\" data-id=\"d862a82\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>El principio de funcionamiento de un caudal\u00edmetro electromagn\u00e9tico se basa en la conductividad del medio. Las propiedades del medio afectan directamente al rendimiento del caudal\u00edmetro, a su precisi\u00f3n y a la selecci\u00f3n de materiales para revestimientos y electrodos.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5cba8fb e-flex e-con-boxed e-con e-parent\" data-id=\"5cba8fb\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-57469ed elementor-widget elementor-widget-image\" data-id=\"57469ed\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"489\" src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW.png\" class=\"attachment-full size-full wp-image-23437\" alt=\"Planta de tratamiento de aguas residuales PLC, 1,5 kW, 1-3 kW\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW.png 1000w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW-300x147.png 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW-768x376.png 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW-340x166.png 340w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1623ca2 e-flex e-con-boxed e-con e-parent\" data-id=\"1623ca2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1567983 elementor-widget elementor-widget-text-editor\" data-id=\"1567983\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\">Aguas residuales PLC Estaci\u00f3n depuradora de aguas residuales<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65f0b97 elementor-widget elementor-widget-menu-anchor\" data-id=\"65f0b97\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"2\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c98c337 e-flex e-con-boxed e-con e-parent\" data-id=\"c98c337\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d94d0b8 elementor-widget elementor-widget-text-editor\" data-id=\"d94d0b8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Los principales factores a tener en cuenta son:<\/p>\n<h4>1 . Requisitos de conductividad<\/h4>\n<p>Los caudal\u00edmetros electromagn\u00e9ticos requieren que el medio tenga un determinado nivel de conductividad. Normalmente, los caudal\u00edmetros electromagn\u00e9ticos est\u00e1n dise\u00f1ados para medir fluidos con un rango de conductividad de <strong>10-\u2074 S\/cm<\/strong> a <strong>5\u00d710-\u2076 S\/cm<\/strong>. Si la conductividad del medio est\u00e1 por debajo de este umbral, pueden producirse errores de medici\u00f3n o un fallo completo. Para fluidos de baja conductividad (por ejemplo, ciertos aceites), pueden ser necesarios caudal\u00edmetros con mayor sensibilidad o dise\u00f1os especializados.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7885ace e-flex e-con-boxed e-con e-parent\" data-id=\"7885ace\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5d7d4f4 elementor-widget elementor-widget-image\" data-id=\"5d7d4f4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"649\" height=\"365\" src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Magnetic-flowmeter-1-1300x7311121-1.png\" class=\"attachment-full size-full wp-image-25116\" alt=\"Caudal\u00edmetro magn\u00e9tico\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Magnetic-flowmeter-1-1300x7311121-1.png 649w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Magnetic-flowmeter-1-1300x7311121-1-300x169.png 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Magnetic-flowmeter-1-1300x7311121-1-340x191.png 340w\" sizes=\"(max-width: 649px) 100vw, 649px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-326b5f2 elementor-widget elementor-widget-menu-anchor\" data-id=\"326b5f2\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"3\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db65a45 elementor-widget elementor-widget-text-editor\" data-id=\"db65a45\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>2 . Composici\u00f3n del medio y burbujas de gas<\/h4>\n<p><span style=\"text-decoration: underline;\"><strong>Part\u00edculas s\u00f3lidas<\/strong><\/span>: Si el medio contiene part\u00edculas magn\u00e9ticas, como limaduras de hierro, puede interferir con el campo magn\u00e9tico del caudal\u00edmetro, provocando errores de medici\u00f3n. En tales casos, se recomiendan caudal\u00edmetros con capacidad de apantallamiento magn\u00e9tico.<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Burbujas de gas<\/strong><\/span>: La presencia de burbujas en el fluido puede provocar errores de medici\u00f3n, ya que las burbujas contribuir\u00e1n al caudal total. Para mitigarlo, un dispositivo de separaci\u00f3n de burbujas o un caudal\u00edmetro capaz de compensarlas puede mejorar la precisi\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1027a40 elementor-widget elementor-widget-menu-anchor\" data-id=\"1027a40\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"4\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a20e1d7 e-flex e-con-boxed e-con e-parent\" data-id=\"a20e1d7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c6aefd4 elementor-widget elementor-widget-text-editor\" data-id=\"c6aefd4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>3 . Sedimentos e incrustaciones<\/h4>\n<p>Ciertos medios, como el agua con alto contenido en calcio o magnesio, pueden provocar la acumulaci\u00f3n de sedimentos o incrustaciones en el revestimiento de la tuber\u00eda o en los electrodos, afectando a la precisi\u00f3n de la medici\u00f3n. Se recomiendan los electrodos autolimpiables o los caudal\u00edmetros con funciones antisarro. Para los medios propensos a la formaci\u00f3n de incrustaciones, los caudal\u00edmetros con revestimientos cer\u00e1micos o de PTFE pueden reducir el desgaste y las deposiciones.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a3d908d e-flex e-con-boxed e-con e-parent\" data-id=\"a3d908d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3bef5b2 elementor-widget elementor-widget-menu-anchor\" data-id=\"3bef5b2\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"5\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bcc2962 elementor-widget elementor-widget-text-editor\" data-id=\"bcc2962\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>4. Requisitos de higiene y calidad alimentaria<\/h4>\n<p>En industrias como la alimentaria, la farmac\u00e9utica y la qu\u00edmica, los caudal\u00edmetros deben cumplir normas de higiene espec\u00edficas. Los materiales utilizados en el caudal\u00edmetro deben cumplir las normas de calidad alimentaria o GMP, como acero inoxidable, PTFE o PFA, lo que garantiza que el caudal\u00edmetro no reaccione con el medio y sea f\u00e1cil de limpiar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1177a08 e-flex e-con-boxed e-con e-parent\" data-id=\"1177a08\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-77ed398 elementor-widget elementor-widget-menu-anchor\" data-id=\"77ed398\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"6\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30bf039 elementor-widget elementor-widget-text-editor\" data-id=\"30bf039\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>5. Resistencia a la corrosi\u00f3n<\/h4>\n<p>Para medios corrosivos, como l\u00edquidos \u00e1cidos, alcalinos o soluciones qu\u00edmicas, la resistencia a la corrosi\u00f3n del revestimiento y los electrodos del caudal\u00edmetro es fundamental. Se recomiendan materiales como PTFE, PFA o revestimientos cer\u00e1micos para garantizar la durabilidad a largo plazo, mientras que los electrodos fabricados con materiales resistentes a la corrosi\u00f3n como el tantalio o el platino ayudar\u00e1n a mantener la precisi\u00f3n y la estabilidad de la medici\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8e2ee5c e-flex e-con-boxed e-con e-parent\" data-id=\"8e2ee5c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c28f6c7 elementor-widget elementor-widget-menu-anchor\" data-id=\"c28f6c7\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"7\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bf793b elementor-widget elementor-widget-heading\" data-id=\"0bf793b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Par\u00e1metros de funcionamiento<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-87c89d9 e-flex e-con-boxed e-con e-parent\" data-id=\"87c89d9\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5585752 elementor-widget elementor-widget-text-editor\" data-id=\"5585752\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>1. Temperatura y presi\u00f3n<\/h4>\n<p>La temperatura y la presi\u00f3n influyen directamente en el rendimiento y la vida \u00fatil de los caudal\u00edmetros electromagn\u00e9ticos. Para fluidos a alta temperatura, deben seleccionarse caudal\u00edmetros con revestimientos que soporten altas temperaturas, como PTFE o PFA. Para entornos de alta presi\u00f3n, se requieren caudal\u00edmetros fabricados con materiales resistentes a la presi\u00f3n para garantizar la seguridad y evitar fugas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eac98f2 elementor-widget elementor-widget-menu-anchor\" data-id=\"eac98f2\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"8\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2950a31 e-flex e-con-boxed e-con e-parent\" data-id=\"2950a31\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-85772eb elementor-widget elementor-widget-text-editor\" data-id=\"85772eb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>2. Coincidencia de di\u00e1metro de tuber\u00eda y rango de caudal<\/h4>\n<p>El di\u00e1metro del caudal\u00edmetro electromagn\u00e9tico debe coincidir con el di\u00e1metro de la tuber\u00eda para garantizar un funcionamiento correcto dentro de su rango de caudal efectivo. Un caudal\u00edmetro con un di\u00e1metro demasiado grande o demasiado peque\u00f1o puede afectar a la precisi\u00f3n de la medici\u00f3n. Para aplicaciones de bajo caudal o baja velocidad, normalmente se recomienda seleccionar un caudal\u00edmetro con un di\u00e1metro ligeramente inferior para mejorar la sensibilidad y la precisi\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9ca39f elementor-widget elementor-widget-menu-anchor\" data-id=\"f9ca39f\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"9\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d5b060a e-flex e-con-boxed e-con e-parent\" data-id=\"d5b060a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89d407 elementor-widget elementor-widget-text-editor\" data-id=\"e89d407\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>3. Velocidad del flujo y flujo a escala completa<\/h4>\n<p>La precisi\u00f3n de medici\u00f3n de un caudal\u00edmetro electromagn\u00e9tico se mantiene estable dentro de un rango espec\u00edfico de velocidades de flujo, normalmente de 1 a 10 m\/s para l\u00edquidos. En la pr\u00e1ctica, velocidades de flujo superiores a 5 m\/s pueden desgastar el revestimiento del caudal\u00edmetro, especialmente si se utilizan materiales m\u00e1s blandos como el caucho. Para aplicaciones de bajo caudal (inferior a 1 m\/s), reducir el di\u00e1metro del caudal\u00edmetro puede ayudar a aumentar la velocidad del caudal y mejorar la intensidad y precisi\u00f3n de la se\u00f1al.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ffbbd0 e-flex e-con-boxed e-con e-parent\" data-id=\"9ffbbd0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f564fc5 elementor-widget elementor-widget-image\" data-id=\"f564fc5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/caudalimetros-magneticos\/\" target=\"_blank\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1011\" height=\"1024\" src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1011x1024.png\" class=\"attachment-large size-large wp-image-23402\" alt=\"Especificaciones del caudal\u00edmetro electromagn\u00e9tico\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1011x1024.png 1011w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-296x300.png 296w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-768x778.png 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-340x344.png 340w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1516x1536.png 1516w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1000x1013.png 1000w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-100x100.png 100w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-46x46.png 46w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1300x1317.png 1300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications.png 1776w\" sizes=\"(max-width: 1011px) 100vw, 1011px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ffa1d76 e-flex e-con-boxed e-con e-parent\" data-id=\"ffa1d76\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9adde8b elementor-widget elementor-widget-menu-anchor\" data-id=\"9adde8b\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"10\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-016abcb elementor-widget elementor-widget-heading\" data-id=\"016abcb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Elegir el nivel de precisi\u00f3n adecuado<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a3864f5 e-flex e-con-boxed e-con e-parent\" data-id=\"a3864f5\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6afadd8 elementor-widget elementor-widget-text-editor\" data-id=\"6afadd8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>El nivel de precisi\u00f3n del caudal\u00edmetro electromagn\u00e9tico es crucial para la precisi\u00f3n de las mediciones. Seleccionar el nivel de precisi\u00f3n adecuado en funci\u00f3n de los requisitos espec\u00edficos ayuda a evitar costes innecesarios.<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Caudal\u00edmetros electromagn\u00e9ticos de alta precisi\u00f3n:<\/strong><\/span> Normalmente, estos caudal\u00edmetros tienen un margen de error de \u00b10,2% a \u00b10,5% y son adecuados para aplicaciones que requieren mediciones muy precisas, como la medici\u00f3n y otros entornos que exigen precisi\u00f3n.<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Caudal\u00edmetros electromagn\u00e9ticos de precisi\u00f3n est\u00e1ndar<\/strong><\/span>: Estos caudal\u00edmetros suelen tener un margen de error de \u00b11% a \u00b12% FS y son adecuados para aplicaciones industriales generales. Ofrecen una buena relaci\u00f3n calidad-precio a la vez que cumplen la mayor\u00eda de los requisitos operativos.<\/p>\n<p>Al seleccionar el nivel de precisi\u00f3n, tenga en cuenta las necesidades espec\u00edficas y el presupuesto. Si no es esencial una alta precisi\u00f3n, optar por un caudal\u00edmetro de precisi\u00f3n est\u00e1ndar puede ayudar a minimizar costes innecesarios.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-af614c3 e-flex e-con-boxed e-con e-parent\" data-id=\"af614c3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38ec947 elementor-widget elementor-widget-image\" data-id=\"38ec947\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1001\" height=\"526\" src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1.png\" class=\"attachment-large size-large wp-image-25117\" alt=\"Imagen del procedimiento de calibraci\u00f3n de un caudal\u00edmetro electromagn\u00e9tico.\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1.png 1001w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1-300x158.png 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1-768x404.png 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1-340x179.png 340w\" sizes=\"(max-width: 1001px) 100vw, 1001px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d98bae1 e-flex e-con-boxed e-con e-parent\" data-id=\"d98bae1\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-df9703d elementor-widget elementor-widget-text-editor\" data-id=\"df9703d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Fuente: <a href=\"https:\/\/automationforum.co\/calibration-procedure-for-electromagnetic-flowmeter\/\" target=\"_blank\" rel=\"noopener\">automatizacionforo.co<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a49d2af e-flex e-con-boxed e-con e-parent\" data-id=\"a49d2af\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d582098 elementor-widget elementor-widget-heading\" data-id=\"d582098\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Magnetic Flow Meter Installation and Troubleshooting<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-316c0ac e-flex e-con-boxed e-con e-parent\" data-id=\"316c0ac\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f127cfa elementor-widget elementor-widget-text-editor\" data-id=\"f127cfa\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/metlaninst.com\/es\/que-precauciones-deben-tomarse-al-utilizar-un-caudalimetro-electromagnetico\/\">\u00bfQu\u00e9 precauciones deben tomarse al utilizar un caudal\u00edmetro electromagn\u00e9tico?<\/a><\/li>\n<li><a href=\"https:\/\/metlaninst.com\/es\/cuales-son-las-consideraciones-relativas-a-la-instalacion-y-el-entorno-de-un-caudalimetro-magnetico\/\">\u00bfCu\u00e1les son las consideraciones relativas a la instalaci\u00f3n y el entorno de un caudal\u00edmetro magn\u00e9tico?<\/a><\/li>\n<li>\u00a0<a href=\"https:\/\/metlaninst.com\/es\/resolucion-de-problemas-de-caudalimetros-electromagneticos-impacto-de-los-contaminantes-gaseosos-y-solidos-casos-practicos\/\"><span class=\"current\">Troubleshooting Electromagnetic Flowmeters: Impact of Gas and Solid Contaminants<\/span><\/a><\/li>\n<li><a href=\"https:\/\/metlaninst.com\/es\/solucion-de-problemas-de-caudalimetros-electromagneticos-debidos-a-cambios-en-las-condiciones-de-caudal\/\">Localizaci\u00f3n de aver\u00edas en caudal\u00edmetros electromagn\u00e9ticos debidas a cambios en las condiciones de caudal<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0acc2dc e-flex e-con-boxed e-con e-parent\" data-id=\"0acc2dc\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2354447 elementor-widget elementor-widget-heading\" data-id=\"2354447\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusi\u00f3n<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b12ff37 e-flex e-con-boxed e-con e-parent\" data-id=\"b12ff37\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b16190c elementor-widget elementor-widget-text-editor\" data-id=\"b16190c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La selecci\u00f3n del caudal\u00edmetro electromagn\u00e9tico adecuado requiere una cuidadosa consideraci\u00f3n de varios factores, incluidas las caracter\u00edsticas del medio medido, los rangos de temperatura y presi\u00f3n de funcionamiento, la velocidad de flujo y la correspondencia de rangos de flujo, as\u00ed como la precisi\u00f3n requerida. Al realizar una selecci\u00f3n informada, puede garantizar el alto rendimiento, la eficacia y la fiabilidad a largo plazo del caudal\u00edmetro electromagn\u00e9tico. Esta gu\u00eda est\u00e1 dise\u00f1ada para ayudarle a elegir de forma cient\u00edfica y precisa el caudal\u00edmetro electromagn\u00e9tico adecuado para sus necesidades.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1f7442b e-flex e-con-boxed e-con e-parent\" data-id=\"1f7442b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e1ac86 elementor-widget elementor-widget-heading\" data-id=\"3e1ac86\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Caudal\u00edmetros magn\u00e9ticos<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c27ffe elementor-widget elementor-widget-ts-products\" data-id=\"6c27ffe\" data-element_type=\"widget\" data-widget_type=\"ts-products.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"ts-product-wrapper ts-shortcode ts-product woocommerce columns-4 best_selling title-default product-default\" >\n\t\t\n\t\t\t\t\t\t\n\t\t\t<div class=\"content-wrapper\">\n\t\t\t\t<div class=\"products\"><section class=\"product type-product post-23196 status-publish first instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23196\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetros-magneticos-sanitarios-mtf-a\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-A-Sanitary-Magnetic-Flow-Meters.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Caudal\u00edmetros magn\u00e9ticos sanitarios MTF-A\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23196\"><span class=\"ts-tooltip button-tooltip\">Vista r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23196\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23196\" data-product_sku=\"MTF-A\" aria-label=\"A\u00f1adir al carrito: \u201cSanitary Magnetic Flow Meters (MTF-A)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abSanitary Magnetic Flow Meters (MTF-A)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetros-magneticos-sanitarios-mtf-a\/\">Caudal\u00edmetro magn\u00e9ticos sanitarios (MTF-A)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23196\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23196\" data-product_sku=\"MTF-A\" aria-label=\"A\u00f1adir al carrito: \u201cSanitary Magnetic Flow Meters (MTF-A)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abSanitary Magnetic Flow Meters (MTF-A)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23199 status-publish instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23199\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-magnetico-para-alta-temperatura-mtf-h\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-H-Magnetic-Flow-Meter-for-High-Temperature-Medium.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Caudal\u00edmetro magn\u00e9tico MTF-H para medios a alta temperatura\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23199\"><span class=\"ts-tooltip button-tooltip\">Vista r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23199\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23199\" data-product_sku=\"MTF-H\" aria-label=\"A\u00f1adir al carrito: \u201cMagnetic Flow Meter for High Temperature Medium (MTF-H)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abMagnetic Flow Meter for High Temperature Medium (MTF-H)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-magnetico-para-alta-temperatura-mtf-h\/\">Caudal\u00edmetro magn\u00e9tico para alta temperatura (MTF-H)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23199\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23199\" data-product_sku=\"MTF-H\" aria-label=\"A\u00f1adir al carrito: \u201cMagnetic Flow Meter for High Temperature Medium (MTF-H)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abMagnetic Flow Meter for High Temperature Medium (MTF-H)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23215 status-publish instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23215\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-electromagnetico-remoto-mtf-f-200\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-F-200-Remote-Electromagnetic-Flow-Meter.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidor de caudal electromagn\u00e9tico remoto MTF-F-200\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23215\"><span class=\"ts-tooltip button-tooltip\">Vista r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23215\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23215\" data-product_sku=\"MTF-F-200\" aria-label=\"A\u00f1adir al carrito: \u201cRemote Electromagnetic Flow Meter (MTF-F-200)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abRemote Electromagnetic Flow Meter (MTF-F-200)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-electromagnetico-remoto-mtf-f-200\/\">Caudal\u00edmetro electromagn\u00e9ticos remoto (MTF-F-200)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23215\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23215\" data-product_sku=\"MTF-F-200\" aria-label=\"A\u00f1adir al carrito: \u201cRemote Electromagnetic Flow Meter (MTF-F-200)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abRemote Electromagnetic Flow Meter (MTF-F-200)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23218 status-publish last instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23218\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-electromagnetico-con-bridas-mtf-f-100\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-F-100-Flanged-Electromagnetic-Flow-Meter.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidor de caudal electromagn\u00e9tico con bridas MTF-F-100\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23218\"><span class=\"ts-tooltip button-tooltip\">Vista r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23218\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23218\" data-product_sku=\"MTF-F-100\" aria-label=\"A\u00f1adir al carrito: \u201cFlanged Electromagnetic Flow Meter (MTF-F-100)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abFlanged Electromagnetic Flow Meter (MTF-F-100)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-electromagnetico-con-bridas-mtf-f-100\/\">Caudal\u00edmetro electromagn\u00e9ticos con bridas (MTF-F-100)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23218\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23218\" data-product_sku=\"MTF-F-100\" aria-label=\"A\u00f1adir al carrito: \u201cFlanged Electromagnetic Flow Meter (MTF-F-100)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abFlanged Electromagnetic Flow Meter (MTF-F-100)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23226 status-publish first instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23226\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-magnetico-a-pilas-mtf-b\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-B-Battery-Powered-Magnetic-Flowmeter.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Caudal\u00edmetro magn\u00e9tico a pilas MTF-B\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23226\"><span class=\"ts-tooltip button-tooltip\">Vista r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23226\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23226\" data-product_sku=\"MTF-B\" aria-label=\"A\u00f1adir al carrito: \u201cBattery Powered Magnetic Flowmeter (MTF-B)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abBattery Powered Magnetic Flowmeter (MTF-B)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-magnetico-a-pilas-mtf-b\/\">Caudal\u00edmetro magn\u00e9tico a pilas (MTF-B)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23226\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23226\" data-product_sku=\"MTF-B\" aria-label=\"A\u00f1adir al carrito: \u201cBattery Powered Magnetic Flowmeter (MTF-B)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abBattery Powered Magnetic Flowmeter (MTF-B)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23230 status-publish instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23230\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetros-magneticos-de-insercion-mtf-i\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-I-Insertion-Magnetic-Flow-Meters-600x600.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Caudal\u00edmetros magn\u00e9ticos de inserci\u00f3n MTF-I\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23230\"><span class=\"ts-tooltip button-tooltip\">Vista r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23230\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23230\" data-product_sku=\"MTF-I\" aria-label=\"A\u00f1adir al carrito: \u201cInsertion Magnetic Flow Meters (MTF-I)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abInsertion Magnetic Flow Meters (MTF-I)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetros-magneticos-de-insercion-mtf-i\/\">Caudal\u00edmetro magn\u00e9ticos de inserci\u00f3n (MTF-I)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23230\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23230\" data-product_sku=\"MTF-I\" aria-label=\"A\u00f1adir al carrito: \u201cInsertion Magnetic Flow Meters (MTF-I)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abInsertion Magnetic Flow Meters (MTF-I)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23234 status-publish instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23234\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-electromagnetico-para-liquidos-de-baja-conductividad-mtf-c\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-C-Electromagnetic-Flowmeter-for-Low-Conductivity-Liquids.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Caudal\u00edmetro electromagn\u00e9tico MTF-C para l\u00edquidos de baja conductividad\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23234\"><span class=\"ts-tooltip button-tooltip\">Vista r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23234\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23234\" data-product_sku=\"MTF-C\" aria-label=\"A\u00f1adir al carrito: \u201cElectromagnetic Flowmeter for Low Conductivity Liquids (MTF-C)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abElectromagnetic Flowmeter for Low Conductivity Liquids (MTF-C)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-electromagnetico-para-liquidos-de-baja-conductividad-mtf-c\/\">Caudal\u00edmetro electromagn\u00e9tico para l\u00edquidos de baja conductividad (MTF-C)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23234\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23234\" data-product_sku=\"MTF-C\" aria-label=\"A\u00f1adir al carrito: \u201cElectromagnetic Flowmeter for Low Conductivity Liquids (MTF-C)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abElectromagnetic Flowmeter for Low Conductivity Liquids (MTF-C)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-22729 status-publish last instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"22729\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-magnetico-para-agua-y-aguas-residuales-mtf-w\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-W-Magnetic-Flow-Meter-for-Water-and-Wastewater.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"MTF-W Caudal\u00edmetro magn\u00e9tico para agua y aguas residuales\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"22729\"><span class=\"ts-tooltip button-tooltip\">Vista r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=22729\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"22729\" data-product_sku=\"MTF-W\" aria-label=\"A\u00f1adir al carrito: \u201cMagnetic Flow Meter for Water and Wastewater (MTF-W)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abMagnetic Flow Meter for Water and Wastewater (MTF-W)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/es\/p\/caudalimetro-magnetico-para-agua-y-aguas-residuales-mtf-w\/\">Caudal\u00edmetro magn\u00e9tico para agua y aguas residuales (MTF-W)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=22729\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"22729\" data-product_sku=\"MTF-W\" aria-label=\"A\u00f1adir al carrito: \u201cMagnetic Flow Meter for Water and Wastewater (MTF-W)\u201d\" rel=\"nofollow\" data-success_message=\"\u00abMagnetic Flow Meter for Water and Wastewater (MTF-W)\u00bb se ha a\u00f1adido a tu carrito\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">A\u00f1adir al carrito<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><\/div>\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Los caudal\u00edmetros electromagn\u00e9ticos se utilizan ampliamente en aplicaciones industriales para la medici\u00f3n de caudal, especialmente en l\u00edquidos sin part\u00edculas s\u00f3lidas. Su precisi\u00f3n y fiabilidad son cruciales en muchas industrias. La selecci\u00f3n del caudal\u00edmetro electromagn\u00e9tico adecuado implica tener en cuenta varios factores relacionados con las condiciones de funcionamiento y las caracter\u00edsticas del medio medido. A continuaci\u00f3n se exponen consideraciones clave que le ayudar\u00e1n a [...]<\/p>","protected":false},"author":1,"featured_media":23423,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[124,123],"tags":[174,176,125,126,175],"class_list":["post-23383","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-magnetic-flow-meters","category-flow-meters","tag-electromagnetic-flow-measurement","tag-electromagnetic-flowmeter-principles","tag-flow-meters","tag-magnetic-flow-meters","tag-magnetic-flow-sensors"],"_links":{"self":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/23383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/comments?post=23383"}],"version-history":[{"count":58,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/23383\/revisions"}],"predecessor-version":[{"id":27239,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/23383\/revisions\/27239"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/media\/23423"}],"wp:attachment":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/media?parent=23383"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/categories?post=23383"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/tags?post=23383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}