{"id":25131,"date":"2024-12-04T12:45:48","date_gmt":"2024-12-04T12:45:48","guid":{"rendered":"https:\/\/www.metlaninst.com\/?p=25131"},"modified":"2025-07-13T02:37:25","modified_gmt":"2025-07-13T02:37:25","slug":"solucion-de-problemas-de-caudalimetros-electromagneticos-debidos-a-una-instalacion-incorrecta","status":"publish","type":"post","link":"https:\/\/metlaninst.com\/es\/solucion-de-problemas-de-caudalimetros-electromagneticos-debidos-a-una-instalacion-incorrecta\/","title":{"rendered":"Soluci\u00f3n de problemas en caudal\u00edmetros electromagn\u00e9ticos: Problemas debidos a una instalaci\u00f3n incorrecta"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"25131\" class=\"elementor elementor-25131\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ee27da e-flex e-con-boxed e-con e-parent\" data-id=\"1ee27da\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9b81ddb elementor-widget elementor-widget-text-editor\" data-id=\"9b81ddb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/metlaninst.com\/es\/solucion-de-problemas-de-caudalimetros-electromagneticos-debidos-a-cambios-en-las-condiciones-de-caudal\/\">Troubleshooting electromagnetic flow meters<\/a> can involve a variety of factors, with improper installation being one of the most common causes. The following outlines the types of faults caused by improper installation, along with a case study.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-05c442c e-flex e-con-boxed e-con e-parent\" data-id=\"05c442c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0275fb6 elementor-widget elementor-widget-text-editor\" data-id=\"0275fb6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Problemas comunes de instalaci\u00f3n:<\/p><ul><li><span style=\"text-decoration: underline;\"><strong>Desajuste entre el caudal\u00edmetro y el di\u00e1metro interior de la tuber\u00eda<\/strong><\/span>: Si existe una diferencia significativa entre el di\u00e1metro interior del caudal\u00edmetro y el de la tuber\u00eda de conexi\u00f3n (de acuerdo con la norma ISO 9141:1991, a menos que el fabricante recomiende otra cosa, el di\u00e1metro de la tuber\u00eda no debe ser inferior al di\u00e1metro interior del caudal\u00edmetro, ni superar los 3% del di\u00e1metro interior).<\/li><li><span style=\"text-decoration: underline;\"><strong>Junta que sobresale en el paso de caudal<\/strong><\/span>: Cuando la junta sobresale en el paso del caudal durante la conexi\u00f3n del caudal\u00edmetro a la tuber\u00eda, puede obstruir la medici\u00f3n del caudal.<\/li><li><span style=\"text-decoration: underline;\"><strong>Perturbaci\u00f3n del caudal causada por accesorios aguas arriba<\/strong><\/span>: El flujo irregular o en remolino causado por accesorios aguas arriba, o una longitud insuficiente de la tuber\u00eda recta antes del caudal\u00edmetro, puede distorsionar significativamente la distribuci\u00f3n de la velocidad del flujo.<\/li><\/ul><p>Estos problemas de instalaci\u00f3n pueden provocar discrepancias en las mediciones y, en algunos casos, causar fluctuaciones o inestabilidad en la producci\u00f3n.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-98a3933 e-flex e-con-boxed e-con e-parent\" data-id=\"98a3933\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1296c7b elementor-widget elementor-widget-text-editor\" data-id=\"1296c7b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Estudio de caso:<\/h4><p>En una planta de tratamiento de aguas de Shanghai, se utilizaron dos caudal\u00edmetros electromagn\u00e9ticos DN400 conectados en serie para medir el agua terminada en dos tuber\u00edas. El primer caudal\u00edmetro estaba situado aproximadamente 5 metros aguas abajo de una v\u00e1lvula de mariposa totalmente abierta, y el segundo caudal\u00edmetro estaba situado unos 2,5 metros m\u00e1s aguas abajo. El tramo de tuber\u00eda recta aguas arriba era ligeramente insuficiente en longitud. Tras la puesta en servicio en 1997, se observ\u00f3 una discrepancia de 15% entre las lecturas de los dos caudal\u00edmetros en una tuber\u00eda. Seis meses despu\u00e9s, la discrepancia se redujo ligeramente a 10%. A pesar de las exhaustivas inspecciones y an\u00e1lisis, no se pudo identificar la causa del fallo y el problema qued\u00f3 sin resolver.<\/p><p>No fue hasta finales de 1998, cuando se retir\u00f3 el caudal\u00edmetro, <span style=\"text-decoration: underline;\"><strong>que se encontraron grandes trozos de revestimiento de cemento desprendidos en la tuber\u00eda de entrada, acumul\u00e1ndose hasta 300-350 mm de altura<\/strong><\/span>. Estos dep\u00f3sitos distorsionaron gravemente la distribuci\u00f3n de la velocidad del caudal que entraba en el caudal\u00edmetro, con una obstrucci\u00f3n en la parte inferior de la tuber\u00eda que bloqueaba aproximadamente 0,25D de la secci\u00f3n transversal del caudal. Una vez eliminada la obstrucci\u00f3n, la medici\u00f3n volvi\u00f3 a la normalidad. La reducci\u00f3n de la discrepancia de 15% a 10% puede explicarse por la altura inicial de los residuos acumulados, superior a 300-350 mm, que disminuy\u00f3 con el tiempo debido al efecto de lavado del caudal, lo que dio lugar a una reducci\u00f3n de la discrepancia.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad12d3d e-flex e-con-boxed e-con e-parent\" data-id=\"ad12d3d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a5b50c elementor-widget elementor-widget-text-editor\" data-id=\"3a5b50c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Conclusi\u00f3n:<\/h4><p>Al instalar caudal\u00edmetros, es esencial asegurarse de que el di\u00e1metro de la tuber\u00eda coincide con el di\u00e1metro interior del caudal\u00edmetro, evitar interferencias de juntas en el paso del caudal y asegurarse de que la secci\u00f3n recta de la tuber\u00eda tiene la longitud suficiente. En el caso de los caudal\u00edmetros de gran di\u00e1metro, la inspecci\u00f3n interna de la tuber\u00eda s\u00f3lo debe realizarse despu\u00e9s de detener el flujo. Este procedimiento suele realizarse como \u00faltimo recurso, una vez descartados otros posibles fallos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62083c5 elementor-widget elementor-widget-text-editor\" data-id=\"62083c5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h5>No dude en ponerse en contacto con nosotros si necesita asistencia t\u00e9cnica.<\/h5>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8342df6 elementor-widget elementor-widget-wpforms\" data-id=\"8342df6\" data-element_type=\"widget\" data-widget_type=\"wpforms.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"wpforms-container wpforms-container-full wpforms-render-modern\" id=\"wpforms-24193\"><form id=\"wpforms-form-24193\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"24193\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/es\/wp-json\/wp\/v2\/posts\/25131\" data-token=\"db832026d55b32f0a1b99938c2e61330\" data-token-time=\"1777059515\" data-trp-original-action=\"\/es\/wp-json\/wp\/v2\/posts\/25131\"><noscript class=\"wpforms-error-noscript\">Por favor, active JavaScript en su navegador para completar este formulario.<\/noscript><div class=\"wpforms-hidden\" id=\"wpforms-error-noscript\">Por favor, active JavaScript en su navegador para completar este formulario.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-24193-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Nombre <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-medium\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-24193-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-24193-field_1-error\" required><label for=\"wpforms-24193-field_1\" class=\"wpforms-field-sublabel after\">Nombre<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-24193-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-24193-field_1-last-error\" required><label for=\"wpforms-24193-field_1-last\" class=\"wpforms-field-sublabel after\">Apellidos<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-24193-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-24193-field_2\">Correo electr\u00f3nico <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-24193-field_2\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-24193-field_2-error\" required><\/div><div id=\"wpforms-24193-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-24193-field_3\">Comentario o mensaje<\/label><textarea id=\"wpforms-24193-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-24193-field_3-error\" ><\/textarea><\/div><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"24193\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/25131\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-24193\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Enviar<\/button><img decoding=\"async\" src=\"https:\/\/metlaninst.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Cargando\"><\/div><input type=\"hidden\" name=\"trp-form-language\" value=\"es\"\/><\/form><\/div>  <!-- .wpforms-container -->\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>La localizaci\u00f3n de aver\u00edas en los caudal\u00edmetros electromagn\u00e9ticos puede deberse a diversos factores, siendo la instalaci\u00f3n incorrecta una de las causas m\u00e1s comunes. A continuaci\u00f3n se describen los tipos de fallos causados por una instalaci\u00f3n incorrecta, junto con un caso pr\u00e1ctico. Problemas comunes de instalaci\u00f3n: Desajuste entre el caudal\u00edmetro y el di\u00e1metro interior de la tuber\u00eda: Si existe una diferencia significativa entre [...]<\/p>","protected":false},"author":1,"featured_media":25146,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[123,193,124,186],"tags":[194,125,126,185],"class_list":["post-25131","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-meters","category-electromagnetic-flowmeter-tech-support","category-magnetic-flow-meters","category-technical-support","tag-electromagnetic-flow-meter-tech-support","tag-flow-meters","tag-magnetic-flow-meters","tag-technical-support"],"_links":{"self":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/25131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/comments?post=25131"}],"version-history":[{"count":11,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/25131\/revisions"}],"predecessor-version":[{"id":27260,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/25131\/revisions\/27260"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/media\/25146"}],"wp:attachment":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/media?parent=25131"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/categories?post=25131"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/tags?post=25131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}