{"id":25283,"date":"2024-12-06T03:30:57","date_gmt":"2024-12-06T03:30:57","guid":{"rendered":"https:\/\/www.metlaninst.com\/?p=25283"},"modified":"2025-07-13T02:39:26","modified_gmt":"2025-07-13T02:39:26","slug":"solucion-de-problemas-de-caudalimetros-electromagneticos-debidos-a-cambios-en-las-condiciones-de-caudal","status":"publish","type":"post","link":"https:\/\/metlaninst.com\/es\/solucion-de-problemas-de-caudalimetros-electromagneticos-debidos-a-cambios-en-las-condiciones-de-caudal\/","title":{"rendered":"Localizaci\u00f3n de aver\u00edas en caudal\u00edmetros electromagn\u00e9ticos debidas a cambios en las condiciones de caudal"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"25283\" class=\"elementor elementor-25283\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8eb3a97 e-flex e-con-boxed e-con e-parent\" data-id=\"8eb3a97\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5c463ad elementor-widget elementor-widget-text-editor\" data-id=\"5c463ad\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Flow meters can sometimes experience troubleshooting after being in normal operation for a period, due to changes in the flow conditions. Although the occurrence of such <a href=\"https:\/\/metlaninst.com\/es\/solucion-de-problemas-de-caudalimetros-electromagneticos-debidos-a-cambios-en-las-condiciones-de-caudal\/\">magnetic flow meter troubleshooting<\/a> is not common, it should not be overlooked when analyzing potential causes.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-433dae3 e-flex e-con-boxed e-con e-parent\" data-id=\"433dae3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2ee004d elementor-widget elementor-widget-text-editor\" data-id=\"2ee004d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Estudio de caso : Pieza de revestimiento de goma oscilante en el flujo de l\u00edquido<\/h4><p>En este raro caso, una pieza de revestimiento de goma de la tuber\u00eda se desprendi\u00f3 y oscil\u00f3 con el caudal, creando un flujo pulsante. En una planta de extracci\u00f3n de cobre de Jiangxi, se utilizaron varios caudal\u00edmetros electromagn\u00e9ticos para medir lodos que conten\u00edan s\u00f3lidos en polvo. El sistema hab\u00eda funcionado con normalidad durante a\u00f1os. Sin embargo, en julio de 1998, uno de los caudal\u00edmetros DN600 mostr\u00f3 fluctuaciones de salida que oscilaban entre 50% y 100% del fondo de escala.<\/p><p>Tras la inspecci\u00f3n in situ, el propio caudal\u00edmetro parec\u00eda funcionar con normalidad. Las entrevistas y comprobaciones realizadas indicaron que no se hab\u00edan producido cambios en la fuente de caudal ni se hab\u00edan introducido perturbaciones ambientales. En general, el contador, la instalaci\u00f3n y las condiciones ambientales cumpl\u00edan los requisitos. Como no fue posible detener el flujo para inspeccionar las partes ocultas del caudal\u00edmetro y la tuber\u00eda circundante, no se pudo identificar inmediatamente la aver\u00eda.<\/p><p>La causa no se descubri\u00f3 hasta pasado m\u00e1s de un mes, cuando la planta cerr\u00f3 por mantenimiento. <span style=\"text-decoration: underline;\"><strong>Una gran secci\u00f3n del revestimiento de goma de una tuber\u00eda en forma de U situada aguas abajo del sensor de caudal se hab\u00eda desprendido y estaba suspendida en el interior de la tuber\u00eda. El revestimiento oscilaba con el flujo de l\u00edquido, creando perturbaciones en el caudal. El caudal\u00edmetro detectaba fielmente estas perturbaciones, dando lugar a salidas fluctuantes. Tras sustituir la tuber\u00eda en forma de U, cesaron las graves fluctuaciones de salida.<\/strong><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f7fbed3 e-flex e-con-boxed e-con e-parent\" data-id=\"f7fbed3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-84a38fa elementor-widget elementor-widget-text-editor\" data-id=\"84a38fa\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Estudio de caso : Peces nadando en el oleoducto que provocan picos de se\u00f1al<\/h4><p>Este caso, comunicado desde Estados Unidos, se refer\u00eda a un caudal\u00edmetro electromagn\u00e9tico de gran di\u00e1metro que controlaba el caudal de agua de mar de refrigeraci\u00f3n en el condensador de una central t\u00e9rmica. El caudal\u00edmetro mostraba ocasionalmente grandes picos en la salida registrada. Se realizaron varias inspecciones in situ, pero el ruido transitorio que causaba estos picos no pudo captarse ni localizarse, y no se identific\u00f3 ninguna fuente de ruido el\u00e9ctrico.<\/p><p>Se sugiri\u00f3 que tal vez hubiera peces nadando dentro del caudal\u00edmetro, pero en un principio se descart\u00f3, ya que se cre\u00eda que los peces no pod\u00edan haber entrado en la tuber\u00eda debido a la malla fina de la compuerta de descarga. Sin embargo, tras realizar un experimento, se instal\u00f3 el caudal\u00edmetro en un peque\u00f1o tanque y se coloc\u00f3 un pez de colores cerca del sensor. El caudal\u00edmetro registr\u00f3 inmediatamente picos agudos en la salida cuando el pez nad\u00f3 cerca de \u00e9l. <span style=\"text-decoration: underline;\"><strong>Investigaciones posteriores revelaron que, efectivamente, los peces hab\u00edan entrado en la tuber\u00eda de descarga a trav\u00e9s de la rejilla de malla y se hab\u00edan convertido en peces de mayor tama\u00f1o, causando las fluctuaciones observadas en la salida del caudal\u00edmetro.<\/strong><\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-4917784 e-flex e-con-boxed e-con e-parent\" data-id=\"4917784\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a9879a1 elementor-widget elementor-widget-text-editor\" data-id=\"a9879a1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Resumen<\/h4><p>Estos casos ponen de relieve la importancia de tener en cuenta los cambios en las condiciones de flujo, como objetos f\u00edsicos (como pezoneras desprendidas o peces), que pueden causar aver\u00edas inesperadas o perturbaciones de la se\u00f1al en los caudal\u00edmetros electromagn\u00e9ticos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2875b01 e-flex e-con-boxed e-con e-parent\" data-id=\"2875b01\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e2cb3e5 elementor-widget elementor-widget-text-editor\" data-id=\"e2cb3e5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h5>No dude en ponerse en contacto con nosotros si necesita asistencia t\u00e9cnica.<\/h5>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f0ad5c2 e-flex e-con-boxed e-con e-parent\" data-id=\"f0ad5c2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c56b11e elementor-widget elementor-widget-wpforms\" data-id=\"c56b11e\" data-element_type=\"widget\" data-widget_type=\"wpforms.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"wpforms-container wpforms-container-full wpforms-render-modern\" id=\"wpforms-24193\"><form id=\"wpforms-form-24193\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"24193\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/es\/wp-json\/wp\/v2\/posts\/25283\" data-token=\"e89b403204e6fc6629d37526c1b1f163\" data-token-time=\"1777397080\" data-trp-original-action=\"\/es\/wp-json\/wp\/v2\/posts\/25283\"><noscript class=\"wpforms-error-noscript\">Por favor, active JavaScript en su navegador para completar este formulario.<\/noscript><div class=\"wpforms-hidden\" id=\"wpforms-error-noscript\">Por favor, active JavaScript en su navegador para completar este formulario.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-24193-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Nombre <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-medium\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-24193-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-24193-field_1-error\" required><label for=\"wpforms-24193-field_1\" class=\"wpforms-field-sublabel after\">Nombre<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-24193-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-24193-field_1-last-error\" required><label for=\"wpforms-24193-field_1-last\" class=\"wpforms-field-sublabel after\">Apellidos<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-24193-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-24193-field_2\">Correo electr\u00f3nico <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-24193-field_2\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-24193-field_2-error\" required><\/div><div id=\"wpforms-24193-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-24193-field_3\">Comentario o mensaje<\/label><textarea id=\"wpforms-24193-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-24193-field_3-error\" ><\/textarea><\/div><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"24193\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/25283\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-24193\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Enviar<\/button><img decoding=\"async\" src=\"https:\/\/metlaninst.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Cargando\"><\/div><input type=\"hidden\" name=\"trp-form-language\" value=\"es\"\/><\/form><\/div>  <!-- .wpforms-container -->\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Flow meters can sometimes experience troubleshooting after being in normal operation for a period, due to changes in the flow conditions. Although the occurrence of such magnetic flow meter troubleshooting is not common, it should not be overlooked when analyzing potential causes. Case Study : Oscillating Rubber Liner Piece in the Liquid Flow This rare [&hellip;]<\/p>","protected":false},"author":1,"featured_media":25284,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[193,123,124,186],"tags":[194,125,126,185],"class_list":["post-25283","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electromagnetic-flowmeter-tech-support","category-flow-meters","category-magnetic-flow-meters","category-technical-support","tag-electromagnetic-flow-meter-tech-support","tag-flow-meters","tag-magnetic-flow-meters","tag-technical-support"],"_links":{"self":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/25283","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/comments?post=25283"}],"version-history":[{"count":7,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/25283\/revisions"}],"predecessor-version":[{"id":27263,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/posts\/25283\/revisions\/27263"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/media\/25284"}],"wp:attachment":[{"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/media?parent=25283"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/categories?post=25283"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/metlaninst.com\/es\/wp-json\/wp\/v2\/tags?post=25283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}