{"id":25131,"date":"2024-12-04T12:45:48","date_gmt":"2024-12-04T12:45:48","guid":{"rendered":"https:\/\/www.metlaninst.com\/?p=25131"},"modified":"2025-07-13T02:37:25","modified_gmt":"2025-07-13T02:37:25","slug":"problemes-de-depannage-des-debitmetres-electromagnetiques-dus-a-une-mauvaise-installation","status":"publish","type":"post","link":"https:\/\/metlaninst.com\/fr\/problemes-de-depannage-des-debitmetres-electromagnetiques-dus-a-une-mauvaise-installation\/","title":{"rendered":"D\u00e9pannage des d\u00e9bitm\u00e8tres \u00e9lectromagn\u00e9tiques : Probl\u00e8mes dus \u00e0 une mauvaise installation"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"25131\" class=\"elementor elementor-25131\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1ee27da e-flex e-con-boxed e-con e-parent\" data-id=\"1ee27da\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9b81ddb elementor-widget elementor-widget-text-editor\" data-id=\"9b81ddb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https:\/\/metlaninst.com\/fr\/depannage-des-debitmetres-electromagnetiques-en-raison-de-changements-dans-les-conditions-decoulement\/\">Troubleshooting electromagnetic flow meters<\/a> can involve a variety of factors, with improper installation being one of the most common causes. The following outlines the types of faults caused by improper installation, along with a case study.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-05c442c e-flex e-con-boxed e-con e-parent\" data-id=\"05c442c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0275fb6 elementor-widget elementor-widget-text-editor\" data-id=\"0275fb6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Probl\u00e8mes d'installation courants :<\/p><ul><li><span style=\"text-decoration: underline;\"><strong>Inad\u00e9quation entre le d\u00e9bitm\u00e8tre et le diam\u00e8tre int\u00e9rieur du tuyau<\/strong><\/span>: S'il existe une diff\u00e9rence significative entre le diam\u00e8tre int\u00e9rieur du d\u00e9bitm\u00e8tre et la canalisation de raccordement (conform\u00e9ment \u00e0 la norme ISO 9141:1991, sauf recommandation contraire du fabricant, le diam\u00e8tre de la canalisation ne doit pas \u00eatre inf\u00e9rieur au diam\u00e8tre int\u00e9rieur du d\u00e9bitm\u00e8tre, ni d\u00e9passer 3% du diam\u00e8tre int\u00e9rieur).<\/li><li><span style=\"text-decoration: underline;\"><strong>Joint faisant saillie dans le circuit d'\u00e9coulement<\/strong><\/span>: Lorsque le joint fait saillie dans la voie d'\u00e9coulement pendant le raccordement du d\u00e9bitm\u00e8tre \u00e0 la canalisation, il peut obstruer la mesure du d\u00e9bit.<\/li><li><span style=\"text-decoration: underline;\"><strong>Perturbation de l'\u00e9coulement caus\u00e9e par les raccords en amont<\/strong><\/span>: Un \u00e9coulement irr\u00e9gulier ou tourbillonnant caus\u00e9 par des raccords en amont, ou une longueur de tuyau rectiligne insuffisante avant le d\u00e9bitm\u00e8tre, peut fausser de mani\u00e8re significative la distribution de la vitesse de l'\u00e9coulement.<\/li><\/ul><p>Ces probl\u00e8mes d'installation peuvent entra\u00eener des \u00e9carts de mesure et, dans certains cas, des fluctuations ou une instabilit\u00e9 de la production.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-98a3933 e-flex e-con-boxed e-con e-parent\" data-id=\"98a3933\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1296c7b elementor-widget elementor-widget-text-editor\" data-id=\"1296c7b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>\u00c9tude de cas :<\/h4><p>Dans une usine de traitement des eaux \u00e0 Shanghai, deux d\u00e9bitm\u00e8tres \u00e9lectromagn\u00e9tiques DN400 connect\u00e9s en s\u00e9rie ont \u00e9t\u00e9 utilis\u00e9s pour mesurer l'eau finie dans deux canalisations. Le premier d\u00e9bitm\u00e8tre \u00e9tait situ\u00e9 \u00e0 environ 5 m\u00e8tres en aval d'une vanne papillon compl\u00e8tement ouverte, le second d\u00e9bitm\u00e8tre \u00e9tant situ\u00e9 \u00e0 environ 2,5 m\u00e8tres en aval. La section droite de la conduite en amont \u00e9tait d'une longueur l\u00e9g\u00e8rement insuffisante. Apr\u00e8s la mise en service en 1997, un \u00e9cart de 15% a \u00e9t\u00e9 observ\u00e9 entre les relev\u00e9s des deux d\u00e9bitm\u00e8tres sur une canalisation. Six mois plus tard, l'\u00e9cart s'est l\u00e9g\u00e8rement r\u00e9duit \u00e0 10%. Malgr\u00e9 des inspections et des analyses approfondies, la cause de la d\u00e9faillance n'a pu \u00eatre identifi\u00e9e et le probl\u00e8me n'a pas \u00e9t\u00e9 r\u00e9solu.<\/p><p>Ce n'est qu'\u00e0 la fin de 1998 que le d\u00e9bitm\u00e8tre a \u00e9t\u00e9 retir\u00e9, <span style=\"text-decoration: underline;\"><strong>de gros morceaux de rev\u00eatement en ciment se sont d\u00e9tach\u00e9s de la conduite d'amen\u00e9e, s'accumulant jusqu'\u00e0 300-350 mm de hauteur<\/strong><\/span>. Ces d\u00e9p\u00f4ts ont gravement fauss\u00e9 la distribution de la vitesse du flux entrant dans le d\u00e9bitm\u00e8tre, une obstruction dans la partie inf\u00e9rieure de la conduite bloquant environ 0,25D de la section transversale du flux. Une fois l'obstruction \u00e9limin\u00e9e, la mesure est revenue \u00e0 la normale. La r\u00e9duction de l'\u00e9cart de 15% \u00e0 10% peut s'expliquer par le fait que la hauteur initiale des d\u00e9bris accumul\u00e9s \u00e9tait sup\u00e9rieure \u00e0 300-350 mm et qu'elle a diminu\u00e9 avec le temps gr\u00e2ce \u00e0 l'effet de rin\u00e7age de l'\u00e9coulement, ce qui a r\u00e9duit l'\u00e9cart.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ad12d3d e-flex e-con-boxed e-con e-parent\" data-id=\"ad12d3d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3a5b50c elementor-widget elementor-widget-text-editor\" data-id=\"3a5b50c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>Conclusion :<\/h4><p>Lors de l'installation des d\u00e9bitm\u00e8tres, il est essentiel de veiller \u00e0 ce que le diam\u00e8tre de la conduite corresponde au diam\u00e8tre int\u00e9rieur du d\u00e9bitm\u00e8tre, d'\u00e9viter toute interf\u00e9rence des joints dans la voie d'\u00e9coulement et de s'assurer que la section droite de la conduite est d'une longueur suffisante. Pour les d\u00e9bitm\u00e8tres de grand diam\u00e8tre, l'inspection interne de la canalisation ne doit \u00eatre effectu\u00e9e qu'apr\u00e8s avoir interrompu l'\u00e9coulement. Cette proc\u00e9dure est g\u00e9n\u00e9ralement effectu\u00e9e en dernier recours, une fois que les autres d\u00e9fauts potentiels ont \u00e9t\u00e9 \u00e9limin\u00e9s.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-62083c5 elementor-widget elementor-widget-text-editor\" data-id=\"62083c5\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h5>N'h\u00e9sitez pas \u00e0 nous contacter pour toute assistance technique.<\/h5>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8342df6 elementor-widget elementor-widget-wpforms\" data-id=\"8342df6\" data-element_type=\"widget\" data-widget_type=\"wpforms.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"wpforms-container wpforms-container-full wpforms-render-modern\" id=\"wpforms-24193\"><form id=\"wpforms-form-24193\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"24193\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/fr\/wp-json\/wp\/v2\/posts\/25131\" data-token=\"db832026d55b32f0a1b99938c2e61330\" data-token-time=\"1777004238\" data-trp-original-action=\"\/fr\/wp-json\/wp\/v2\/posts\/25131\"><noscript class=\"wpforms-error-noscript\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/noscript><div class=\"wpforms-hidden\" id=\"wpforms-error-noscript\">Veuillez activer JavaScript dans votre navigateur pour remplir ce formulaire.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-24193-field_1-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"1\"><fieldset><legend class=\"wpforms-field-label\">Nom <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/legend><div class=\"wpforms-field-row wpforms-field-medium\"><div class=\"wpforms-field-row-block wpforms-first wpforms-one-half\"><input type=\"text\" id=\"wpforms-24193-field_1\" class=\"wpforms-field-name-first wpforms-field-required\" name=\"wpforms[fields][1][first]\" aria-errormessage=\"wpforms-24193-field_1-error\" required><label for=\"wpforms-24193-field_1\" class=\"wpforms-field-sublabel after\">Pr\u00e9nom<\/label><\/div><div class=\"wpforms-field-row-block wpforms-one-half\"><input type=\"text\" id=\"wpforms-24193-field_1-last\" class=\"wpforms-field-name-last wpforms-field-required\" name=\"wpforms[fields][1][last]\" aria-errormessage=\"wpforms-24193-field_1-last-error\" required><label for=\"wpforms-24193-field_1-last\" class=\"wpforms-field-sublabel after\">Nom<\/label><\/div><\/div><\/fieldset><\/div><div id=\"wpforms-24193-field_2-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-24193-field_2\">Courriel <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-24193-field_2\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][2]\" spellcheck=\"false\" aria-errormessage=\"wpforms-24193-field_2-error\" required><\/div><div id=\"wpforms-24193-field_3-container\" class=\"wpforms-field wpforms-field-textarea\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-24193-field_3\">Commentaire ou message<\/label><textarea id=\"wpforms-24193-field_3\" class=\"wpforms-field-medium\" name=\"wpforms[fields][3]\" aria-errormessage=\"wpforms-24193-field_3-error\" ><\/textarea><\/div><\/div><!-- .wpforms-field-container --><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"24193\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts\/25131\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-24193\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Submit\" aria-live=\"assertive\" value=\"wpforms-submit\">Soumettre<\/button><img decoding=\"async\" src=\"https:\/\/metlaninst.com\/wp-content\/plugins\/wpforms-lite\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"Chargement en cours\"><\/div><input type=\"hidden\" name=\"trp-form-language\" value=\"fr\"\/><\/form><\/div>  <!-- .wpforms-container -->\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Le d\u00e9pannage des d\u00e9bitm\u00e8tres \u00e9lectromagn\u00e9tiques peut impliquer divers facteurs, une mauvaise installation \u00e9tant l'une des causes les plus courantes. Les paragraphes suivants d\u00e9crivent les types de d\u00e9fauts caus\u00e9s par une mauvaise installation, ainsi qu'une \u00e9tude de cas. Probl\u00e8mes d'installation courants : Inad\u00e9quation entre le d\u00e9bitm\u00e8tre et le diam\u00e8tre int\u00e9rieur de la conduite : S'il existe une diff\u00e9rence significative entre [...]<\/p>","protected":false},"author":1,"featured_media":25146,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[123,193,124,186],"tags":[194,125,126,185],"class_list":["post-25131","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-meters","category-electromagnetic-flowmeter-tech-support","category-magnetic-flow-meters","category-technical-support","tag-electromagnetic-flow-meter-tech-support","tag-flow-meters","tag-magnetic-flow-meters","tag-technical-support"],"_links":{"self":[{"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts\/25131","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/comments?post=25131"}],"version-history":[{"count":11,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts\/25131\/revisions"}],"predecessor-version":[{"id":27260,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts\/25131\/revisions\/27260"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/media\/25146"}],"wp:attachment":[{"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/media?parent=25131"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/categories?post=25131"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/tags?post=25131"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}