{"id":26803,"date":"2025-05-16T09:47:07","date_gmt":"2025-05-16T09:47:07","guid":{"rendered":"https:\/\/www.metlaninst.com\/?p=26803"},"modified":"2025-07-12T08:11:37","modified_gmt":"2025-07-12T08:11:37","slug":"ce-qui-differencie-nos-debitmetres-massiques-thermiques","status":"publish","type":"post","link":"https:\/\/metlaninst.com\/fr\/ce-qui-differencie-nos-debitmetres-massiques-thermiques\/","title":{"rendered":"En quoi nos d\u00e9bitm\u00e8tres massiques thermiques sont-ils diff\u00e9rents ?"},"content":{"rendered":"<p>Chez Metlan Instruments, nous comprenons qu'une mesure pr\u00e9cise et fiable du d\u00e9bit de gaz est essentielle \u00e0 la r\u00e9ussite de vos op\u00e9rations. C'est pourquoi nos <strong><a href=\"https:\/\/metlaninst.com\/fr\/debitmetres-massiques-thermiques\/\">D\u00e9bitm\u00e8tres massiques thermiques<\/a><\/strong> sont con\u00e7us pour \u00eatre plus performants dans les environnements industriels exigeants, o\u00f9 la s\u00e9curit\u00e9, la pr\u00e9cision et la stabilit\u00e9 \u00e0 long terme sont les plus importantes.<\/p><h3 class=\"wp-block-heading\" id=\"what-makes-our-thermal-mass-flow-meters-different\"><strong>En quoi nos d\u00e9bitm\u00e8tres massiques thermiques sont-ils diff\u00e9rents ?<\/strong><strong><\/strong><\/h3><div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><h2>Table des mati\u00e8res<\/h2><nav><ul><li><a href=\"#1-wide-measuring-range-with-ultra-low-flow-capability\">1. Large plage de mesure avec capacit\u00e9 de d\u00e9bit ultra-faible<\/a><\/li><li><a href=\"#2-explosion-proof-and-ip-67-rated\">2. Antid\u00e9flagrant et conforme \u00e0 la norme IP67<\/a><\/li><li><a href=\"#3-integrated-chip-based-sensors\">3. Integrated Chip-based Sensors<\/a><\/li><li><a href=\"#4-advanced-full-digital-signal-processing\">4. Advanced Full-Digital Signal Processing<\/a><\/li><li><a href=\"#5-flexible-communication-and-display-options\">5. Flexible Communication and Display Options<\/a><\/li><li><a href=\"#6-intelligent-sensor-diagnostics\">6. Intelligent Sensor Diagnostics<\/a><\/li><li><a href=\"#7-oem-service\">7. OEM Service<\/a><\/li><li><a href=\"#thermal-mass-flow-meter-case-study\">Thermal Mass Flow Meter Case Study<\/a><\/li><\/ul><\/nav><\/div><h4 class=\"wp-block-heading\" id=\"1-wide-measuring-range-with-ultra-low-flow-capability\"><strong>1. Large plage de mesure avec capacit\u00e9 de d\u00e9bit ultra-faible<\/strong><strong><\/strong><\/h4><p>Nos d\u00e9bitm\u00e8tres pr\u00e9sentent un rapport de r\u00e9duction exceptionnellement \u00e9lev\u00e9 de 1:2500, permettant des mesures pr\u00e9cises \u00e0 partir de 0,1 Nm\/s jusqu'\u00e0 250 Nm\/s. Ils sont donc id\u00e9aux pour les applications pr\u00e9sentant des d\u00e9bits tr\u00e8s variables ou extr\u00eamement faibles, notamment les conduites de d\u00e9rivation, la d\u00e9tection des fuites et la consommation de gaz d'un seul \u00e9quipement.<\/p><div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\"><div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/metlaninst.com\/fr\/debitmetres-massiques-thermiques\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x.jpg\" alt=\"D\u00e9bitm\u00e8tre massique thermique MT212x\" class=\"wp-image-26804\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x.jpg 800w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-300x300.jpg 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-150x150.jpg 150w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-768x768.jpg 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-340x340.jpg 340w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-120x120.jpg 120w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-12x12.jpg 12w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-600x600.jpg 600w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-100x100.jpg 100w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-46x46.jpg 46w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flow-Meter-MT212x-700x700.jpg 700w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/figure><\/div>\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/metlaninst.com\/fr\/debitmetres-massiques-thermiques\/\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x.jpg\" alt=\"Flotteur de masse thermique Type d&#039;insertion MT211x\" class=\"wp-image-26805\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x.jpg 800w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-300x300.jpg 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-150x150.jpg 150w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-768x768.jpg 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-340x340.jpg 340w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-120x120.jpg 120w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-12x12.jpg 12w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-600x600.jpg 600w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-100x100.jpg 100w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-46x46.jpg 46w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Thermal-Mass-Flowneter-Insertion-type-MT211x-700x700.jpg 700w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/figure><\/div><\/div><h4 class=\"wp-block-heading\" id=\"2-explosion-proof-and-ip-67-rated\"><strong>2. Antid\u00e9flagrant et conforme \u00e0 la norme IP67<\/strong><strong><\/strong><\/h4><p>Certifi\u00e9s pour les zones dangereuses avec les classifications antid\u00e9flagrantes Ex db IIC T6 Gb \/ Ex tb IIIC T80\u00b0C Db, ces compteurs sont con\u00e7us pour fonctionner en toute s\u00e9curit\u00e9 dans des conditions difficiles. Le bo\u00eetier robuste IP67 prot\u00e8ge contre la poussi\u00e8re et les infiltrations d'eau, garantissant des performances fiables dans les environnements ext\u00e9rieurs ou humides.<\/p><div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\"><div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/metlaninst.com\/fr\/p\/insertion-debitmetre-massique-thermique-antideflagrant-mt211x-ex\/\"><img decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex.jpg\" alt=\"D\u00e9bitm\u00e8tre massique thermique antid\u00e9flagrant \u00e0 insertion MT211x-Ex\" class=\"wp-image-26806\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex.jpg 800w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-300x300.jpg 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-150x150.jpg 150w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-768x768.jpg 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-340x340.jpg 340w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-120x120.jpg 120w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-12x12.jpg 12w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-600x600.jpg 600w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-100x100.jpg 100w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-46x46.jpg 46w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Insertion-Explosion-proof-Thermal-Mass-Flow-Meter-MT211x-Ex-700x700.jpg 700w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/figure><\/div>\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><figure class=\"wp-block-image size-full\"><a href=\"https:\/\/metlaninst.com\/fr\/p\/debitmetre-massique-thermique-antideflagrant-mt212x-ex\/\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex.jpg\" alt=\"D\u00e9bitm\u00e8tre massique thermique antid\u00e9flagrant MT212x-Ex\" class=\"wp-image-26807\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex.jpg 800w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-300x300.jpg 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-150x150.jpg 150w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-768x768.jpg 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-340x340.jpg 340w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-120x120.jpg 120w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-12x12.jpg 12w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-600x600.jpg 600w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-100x100.jpg 100w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-46x46.jpg 46w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/Explosion-proof-Thermal-Mass-Flowmeter-MT212x-Ex-700x700.jpg 700w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/a><\/figure><\/div><\/div><h4 class=\"wp-block-heading\" id=\"3-integrated-chip-based-sensors\">3. <strong>Capteurs int\u00e9gr\u00e9s sur puce<\/strong><\/h4><p>Contrairement aux autres fournisseurs de d\u00e9bitm\u00e8tres massiques thermiques qui utilisent des capteurs \u00e0 double sonde enrob\u00e9s dans un adh\u00e9sif conducteur thermique domestique, ce qui entra\u00eene souvent une d\u00e9rive des donn\u00e9es au fil du temps, notre conception int\u00e9gr\u00e9e bas\u00e9e sur une puce garantit une stabilit\u00e9 et une pr\u00e9cision de mesure \u00e0 long terme.<\/p><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"760\" height=\"489\" src=\"https:\/\/www.metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-sensor-difference.png\" alt=\"diff\u00e9rence entre les capteurs de d\u00e9bit massique thermique\" class=\"wp-image-26808\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-sensor-difference.png 760w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-sensor-difference-300x193.png 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-sensor-difference-340x219.png 340w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-sensor-difference-18x12.png 18w\" sizes=\"(max-width: 760px) 100vw, 760px\" \/><\/figure><h4 class=\"wp-block-heading\" id=\"4-advanced-full-digital-signal-processing\">4. <strong>Traitement avanc\u00e9 des signaux enti\u00e8rement num\u00e9riques<\/strong><\/h4><p>Les d\u00e9bitm\u00e8tres Metlan Instruments utilisent un traitement du signal enti\u00e8rement num\u00e9rique pour offrir une plus grande pr\u00e9cision, une meilleure stabilit\u00e9 du point z\u00e9ro et une r\u00e9sistance \u00e0 la d\u00e9rive \u00e0 long terme. Avec une pr\u00e9cision typique de \u00b1(1,5% RD + 0,3% FS) (et une option de haute pr\u00e9cision de \u00b11% RD), vous pouvez faire confiance aux donn\u00e9es pour la surveillance et le contr\u00f4le.<\/p><h4 class=\"wp-block-heading\" id=\"5-flexible-communication-and-display-options\">5. <strong>Options de communication et d'affichage flexibles<\/strong><\/h4><p>Notre <a href=\"https:\/\/metlaninst.com\/fr\/les-debitmetres-massiques-thermiques-un-guide-complet\/\">d\u00e9bitm\u00e8tres massiques thermiques <\/a>support a range of outputs including 4\u201320 mA, pulse, and Modbus RTU (RS485). Wireless communication via Bluetooth is standard, with optional Wi-SUN or 4G modules for remote monitoring. The built-in 2.0\u201d IPS color touchscreen display provides clear readings and convenient touch control.<\/p><figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display.jpg\" alt=\"d\u00e9bitm\u00e8tre massique thermique avec \u00e9cran tactile\" class=\"wp-image-26809\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display.jpg 800w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-300x300.jpg 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-150x150.jpg 150w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-768x768.jpg 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-340x340.jpg 340w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-120x120.jpg 120w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-12x12.jpg 12w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-600x600.jpg 600w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-100x100.jpg 100w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-46x46.jpg 46w, https:\/\/metlaninst.com\/wp-content\/uploads\/2025\/05\/thermal-mass-flow-meter-with-touchscreen-display-700x700.jpg 700w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/figure><h4 class=\"wp-block-heading\" id=\"6-intelligent-sensor-diagnostics\">6. <strong>Diagnostic intelligent des capteurs<\/strong><\/h4><p>Gr\u00e2ce \u00e0 des capacit\u00e9s de diagnostic intelligent int\u00e9gr\u00e9es, nos d\u00e9bitm\u00e8tres peuvent d\u00e9tecter la contamination ou la surchauffe du capteur avant qu'elle n'ait un impact sur la pr\u00e9cision de la mesure. Cette protection proactive permet de r\u00e9duire les besoins de maintenance et de prolonger la dur\u00e9e de vie.<\/p><h4 class=\"wp-block-heading\" id=\"7-oem-service\">7. <strong>Service OEM<\/strong><\/h4><p>Nous sommes fiers de soutenir la personnalisation OEM chez Metlan Instruments, avec une quantit\u00e9 minimale de commande d'un seul exemplaire.<\/p><p>Gr\u00e2ce \u00e0 une technologie de mesure sup\u00e9rieure, une construction de qualit\u00e9 industrielle et des fonctions intelligentes, les d\u00e9bitm\u00e8tres massiques thermiques de Metlan offrent des performances fiables l\u00e0 o\u00f9 cela compte. Que vous g\u00e9riez de l'air comprim\u00e9, du gaz naturel, de l'oxyg\u00e8ne ou des gaz sp\u00e9ciaux, vous pouvez compter sur nous pour vous aider \u00e0 mesurer en toute confiance.<\/p><h4 class=\"wp-block-heading\" id=\"thermal-mass-flow-meter-case-study\">D\u00e9bitm\u00e8tre massique thermique <strong>\u00c9tude de cas<\/strong><\/h4><p><a href=\"https:\/\/metlaninst.com\/fr\/analyse-de-cas-du-debitmetre-massique-thermique-mt221-pour-la-mesure-de-lair-comprime\/\">Analyse de cas du d\u00e9bitm\u00e8tre massique thermique MT221 pour la mesure de l'air comprim\u00e9<\/a><\/p><p><\/p>","protected":false},"excerpt":{"rendered":"<p>Chez Metlan Instruments, nous comprenons qu'une mesure pr\u00e9cise et fiable du d\u00e9bit de gaz est essentielle \u00e0 la r\u00e9ussite de vos op\u00e9rations. C'est pourquoi nos d\u00e9bitm\u00e8tres massiques thermiques sont con\u00e7us pour \u00eatre plus performants dans les environnements industriels exigeants, o\u00f9 la s\u00e9curit\u00e9, la pr\u00e9cision et la stabilit\u00e9 \u00e0 long terme comptent le plus. En quoi nos d\u00e9bitm\u00e8tres massiques thermiques sont-ils diff\u00e9rents ? 1. Large plage de mesure [...]<\/p>","protected":false},"author":1,"featured_media":26810,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[123,232],"tags":[],"class_list":["post-26803","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-meters","category-thermal-mass-flow-meter"],"_links":{"self":[{"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts\/26803","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/comments?post=26803"}],"version-history":[{"count":5,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts\/26803\/revisions"}],"predecessor-version":[{"id":27206,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/posts\/26803\/revisions\/27206"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/media\/26810"}],"wp:attachment":[{"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/media?parent=26803"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/categories?post=26803"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/metlaninst.com\/fr\/wp-json\/wp\/v2\/tags?post=26803"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}