{"id":23383,"date":"2024-11-12T12:44:40","date_gmt":"2024-11-12T12:44:40","guid":{"rendered":"https:\/\/www.metlaninst.com\/?p=23383"},"modified":"2025-07-12T13:49:37","modified_gmt":"2025-07-12T13:49:37","slug":"guia-de-selecao-de-caudalimetros-electromagneticos","status":"publish","type":"post","link":"https:\/\/metlaninst.com\/pt\/guia-de-selecao-de-caudalimetros-electromagneticos\/","title":{"rendered":"Guia de sele\u00e7\u00e3o de caudal\u00edmetros electromagn\u00e9ticos"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"23383\" class=\"elementor elementor-23383\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c79f7ff e-flex e-con-boxed e-con e-parent\" data-id=\"c79f7ff\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-62f4acef elementor-widget elementor-widget-text-editor\" data-id=\"62f4acef\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\"><p><a href=\"https:\/\/metlaninst.com\/pt\/medidores-de-caudal-magneticos\/\" target=\"_blank\" rel=\"noopener\">Medidores de caudal electromagn\u00e9ticos<\/a> s\u00e3o amplamente utilizados em aplica\u00e7\u00f5es industriais para medi\u00e7\u00e3o de caudal, particularmente em l\u00edquidos sem part\u00edculas s\u00f3lidas. A sua precis\u00e3o e fiabilidade s\u00e3o cruciais em muitas ind\u00fastrias. A sele\u00e7\u00e3o do medidor de caudal eletromagn\u00e9tico adequado envolve a considera\u00e7\u00e3o de v\u00e1rios factores relacionados com as condi\u00e7\u00f5es de funcionamento e as carater\u00edsticas do meio medido. Seguem-se considera\u00e7\u00f5es fundamentais para o ajudar a selecionar cientificamente o medidor de caudal eletromagn\u00e9tico mais adequado.<\/p>\n<p>Quer saber o que \u00e9 um medidor de caudal magn\u00e9tico e como funciona? Aqui est\u00e1 um guia completo para <a href=\"https:\/\/metlaninst.com\/pt\/caudalimetro-eletromagnetico-e-principios-de-funcionamento\/\" target=\"_blank\" rel=\"noopener\">medidores de caudal magn\u00e9ticos<\/a>.<\/p><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3e4a446 e-flex e-con-boxed e-con e-parent\" data-id=\"3e4a446\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-05886d9 elementor-widget elementor-widget-heading\" data-id=\"05886d9\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00cdndice<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-83991aa e-flex e-con-boxed e-con e-parent\" data-id=\"83991aa\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-186d349 elementor-widget elementor-widget-text-editor\" data-id=\"186d349\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"#1\">Compreender as carater\u00edsticas do meio medido<\/a><\/li>\n<\/ul>\n<p><a href=\"#2\">1. Requisitos de condutividade<\/a><br \/><a href=\"#3\">2. Composi\u00e7\u00e3o do meio e bolhas de g\u00e1s<\/a><br \/><a href=\"#4\">3. Sedimentos e incrusta\u00e7\u00f5es<\/a><br \/><a href=\"#5\">4.  Requisitos em mat\u00e9ria de higiene e de qualidade alimentar<\/a><br \/><a href=\"#6\">5. Resist\u00eancia \u00e0 corros\u00e3o<\/a><\/p>\n<ul>\n<li><a href=\"#7\">Par\u00e2metros das condi\u00e7\u00f5es de funcionamento<\/a><\/li>\n<\/ul>\n<p><a href=\"#7\">1. Temperatura e press\u00e3o<\/a><br \/><a href=\"#8\">2. Correspond\u00eancia do di\u00e2metro da tubagem e do caudal<\/a><br \/><a href=\"#9\">3. Velocidade do fluxo e fluxo em escala real<\/a><\/p>\n<ul>\n<li><a href=\"#10\">\u00a0Escolher o n\u00edvel de precis\u00e3o correto<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-171e48a elementor-widget elementor-widget-text-editor\" data-id=\"171e48a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Related Posts:<\/p>\n<ul>\n<li><a href=\"https:\/\/metlaninst.com\/pt\/tudo-sobre-medidores-de-caudal-para-polpas-abrasivas\/\">Tudo sobre medidores de caudal para polpas abrasivas<\/a><\/li>\n<li><a href=\"https:\/\/metlaninst.com\/pt\/como-escolher-medidores-de-caudal-para-aguas-residuais\/\">Como escolher medidores de caudal para \u00e1guas residuais<\/a><\/li>\n<li><a href=\"https:\/\/metlaninst.com\/pt\/como-escolher-medidores-de-caudal-de-agua\/\">How to Choose Water Flow Meters<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-acbfbc3 elementor-widget elementor-widget-menu-anchor\" data-id=\"acbfbc3\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"1\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d14e4f7 e-flex e-con-boxed e-con e-parent\" data-id=\"d14e4f7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9267545 elementor-widget elementor-widget-heading\" data-id=\"9267545\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Compreender as carater\u00edsticas do meio medido<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2ea2ab e-flex e-con-boxed e-con e-parent\" data-id=\"b2ea2ab\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d862a82 elementor-widget elementor-widget-text-editor\" data-id=\"d862a82\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>O princ\u00edpio de funcionamento de um medidor de caudal eletromagn\u00e9tico baseia-se na condutividade do meio. As propriedades do meio afectam diretamente o desempenho do medidor de caudal, a precis\u00e3o e a sele\u00e7\u00e3o de materiais para revestimentos e el\u00e9ctrodos.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5cba8fb e-flex e-con-boxed e-con e-parent\" data-id=\"5cba8fb\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-57469ed elementor-widget elementor-widget-image\" data-id=\"57469ed\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"1000\" height=\"489\" src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW.png\" class=\"attachment-full size-full wp-image-23437\" alt=\"Esta\u00e7\u00e3o de tratamento de \u00e1guas residuais PLC, 1,5 kW, 1-3 kW\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW.png 1000w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW-300x147.png 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW-768x376.png 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Waste-Water-PLC-Wastewater-Treatment-Plant-1.5-kW-1-3-kW-340x166.png 340w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1623ca2 e-flex e-con-boxed e-con e-parent\" data-id=\"1623ca2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1567983 elementor-widget elementor-widget-text-editor\" data-id=\"1567983\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\">Esta\u00e7\u00e3o de tratamento de \u00e1guas residuais PLC<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-65f0b97 elementor-widget elementor-widget-menu-anchor\" data-id=\"65f0b97\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"2\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c98c337 e-flex e-con-boxed e-con e-parent\" data-id=\"c98c337\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d94d0b8 elementor-widget elementor-widget-text-editor\" data-id=\"d94d0b8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Os principais factores a considerar s\u00e3o:<\/p>\n<h4>1 . Requisitos de condutividade<\/h4>\n<p>Os medidores de caudal electromagn\u00e9ticos requerem que o meio tenha um determinado n\u00edvel de condutividade. Normalmente, os medidores de caudal electromagn\u00e9ticos s\u00e3o concebidos para medir fluidos com uma gama de condutividade de <strong>10-\u2074 S\/cm<\/strong> para <strong>5\u00d710-\u2076 S\/cm<\/strong>. Se a condutividade do fluido for inferior a este limiar, podem ocorrer erros de medi\u00e7\u00e3o ou falha total. Para fluidos de baixa condutividade (por exemplo, certos \u00f3leos), podem ser necess\u00e1rios medidores de caudal com maior sensibilidade ou concep\u00e7\u00f5es especializadas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-7885ace e-flex e-con-boxed e-con e-parent\" data-id=\"7885ace\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5d7d4f4 elementor-widget elementor-widget-image\" data-id=\"5d7d4f4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"649\" height=\"365\" src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Magnetic-flowmeter-1-1300x7311121-1.png\" class=\"attachment-full size-full wp-image-25116\" alt=\"Medidor de caudal magn\u00e9tico\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Magnetic-flowmeter-1-1300x7311121-1.png 649w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Magnetic-flowmeter-1-1300x7311121-1-300x169.png 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Magnetic-flowmeter-1-1300x7311121-1-340x191.png 340w\" sizes=\"(max-width: 649px) 100vw, 649px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-326b5f2 elementor-widget elementor-widget-menu-anchor\" data-id=\"326b5f2\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"3\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db65a45 elementor-widget elementor-widget-text-editor\" data-id=\"db65a45\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>2 . Composi\u00e7\u00e3o do meio e bolhas de g\u00e1s<\/h4>\n<p><span style=\"text-decoration: underline;\"><strong>Part\u00edculas s\u00f3lidas<\/strong><\/span>: Se o meio contiver part\u00edculas magn\u00e9ticas, como limalhas de ferro, pode interferir com o campo magn\u00e9tico do medidor de caudal, conduzindo a erros de medi\u00e7\u00e3o. Nestes casos, recomenda-se a utiliza\u00e7\u00e3o de caudal\u00edmetros com capacidade de prote\u00e7\u00e3o magn\u00e9tica.<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Bolhas de g\u00e1s<\/strong><\/span>: A presen\u00e7a de bolhas no fluido pode causar erros de medi\u00e7\u00e3o, uma vez que as bolhas contribuir\u00e3o para o caudal total. Para mitigar este problema, um dispositivo de separa\u00e7\u00e3o de bolhas ou um medidor de caudal capaz de compensar as bolhas pode melhorar a precis\u00e3o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1027a40 elementor-widget elementor-widget-menu-anchor\" data-id=\"1027a40\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"4\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a20e1d7 e-flex e-con-boxed e-con e-parent\" data-id=\"a20e1d7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c6aefd4 elementor-widget elementor-widget-text-editor\" data-id=\"c6aefd4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>3 . Sedimentos e incrusta\u00e7\u00f5es<\/h4>\n<p>Certos meios, como a \u00e1gua com elevado teor de c\u00e1lcio ou magn\u00e9sio, podem provocar a acumula\u00e7\u00e3o de sedimentos ou incrusta\u00e7\u00f5es no revestimento da tubagem ou nos el\u00e9ctrodos, afectando a precis\u00e3o da medi\u00e7\u00e3o. Recomenda-se a utiliza\u00e7\u00e3o de el\u00e9ctrodos auto-limpantes ou de caudal\u00edmetros com carater\u00edsticas anti-incrustantes. Para meios propensos a incrusta\u00e7\u00f5es, os caudal\u00edmetros com revestimentos de cer\u00e2mica ou PTFE podem reduzir o desgaste e a deposi\u00e7\u00e3o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a3d908d e-flex e-con-boxed e-con e-parent\" data-id=\"a3d908d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3bef5b2 elementor-widget elementor-widget-menu-anchor\" data-id=\"3bef5b2\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"5\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bcc2962 elementor-widget elementor-widget-text-editor\" data-id=\"bcc2962\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>4. Requisitos em mat\u00e9ria de higiene e de qualidade alimentar<\/h4>\n<p>Em ind\u00fastrias como a alimentar, a farmac\u00eautica e a qu\u00edmica, os medidores de caudal t\u00eam de cumprir normas de higiene espec\u00edficas. Os materiais utilizados no medidor de caudal devem estar em conformidade com as normas de qualidade alimentar ou GMP, como o a\u00e7o inoxid\u00e1vel, PTFE ou PFA, garantindo que o medidor de caudal n\u00e3o reage com o meio e \u00e9 f\u00e1cil de limpar.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1177a08 e-flex e-con-boxed e-con e-parent\" data-id=\"1177a08\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-77ed398 elementor-widget elementor-widget-menu-anchor\" data-id=\"77ed398\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"6\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30bf039 elementor-widget elementor-widget-text-editor\" data-id=\"30bf039\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>5. Resist\u00eancia \u00e0 corros\u00e3o<\/h4>\n<p>Para meios corrosivos, tais como l\u00edquidos \u00e1cidos, alcalinos ou solu\u00e7\u00f5es qu\u00edmicas, a resist\u00eancia \u00e0 corros\u00e3o do revestimento do medidor de caudal e dos el\u00e9ctrodos \u00e9 fundamental. Materiais como PTFE, PFA ou revestimentos cer\u00e2micos s\u00e3o recomendados para garantir uma durabilidade a longo prazo, enquanto os el\u00e9ctrodos feitos de materiais resistentes \u00e0 corros\u00e3o, como t\u00e2ntalo ou platina, ajudar\u00e3o a manter a precis\u00e3o e a estabilidade da medi\u00e7\u00e3o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8e2ee5c e-flex e-con-boxed e-con e-parent\" data-id=\"8e2ee5c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c28f6c7 elementor-widget elementor-widget-menu-anchor\" data-id=\"c28f6c7\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"7\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bf793b elementor-widget elementor-widget-heading\" data-id=\"0bf793b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Par\u00e2metros das condi\u00e7\u00f5es de funcionamento<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-87c89d9 e-flex e-con-boxed e-con e-parent\" data-id=\"87c89d9\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5585752 elementor-widget elementor-widget-text-editor\" data-id=\"5585752\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>1. Temperatura e press\u00e3o<\/h4>\n<p>A temperatura e a press\u00e3o influenciam diretamente o desempenho e a vida \u00fatil dos medidores de caudal electromagn\u00e9ticos. Para fluidos a alta temperatura, os medidores de caudal devem ser selecionados com revestimentos que possam suportar altas temperaturas, como PTFE ou PFA. Para ambientes de alta press\u00e3o, s\u00e3o necess\u00e1rios caudal\u00edmetros feitos de materiais resistentes \u00e0 press\u00e3o para garantir a seguran\u00e7a e evitar fugas.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eac98f2 elementor-widget elementor-widget-menu-anchor\" data-id=\"eac98f2\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"8\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2950a31 e-flex e-con-boxed e-con e-parent\" data-id=\"2950a31\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-85772eb elementor-widget elementor-widget-text-editor\" data-id=\"85772eb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>2. Correspond\u00eancia do di\u00e2metro da tubagem e do caudal<\/h4>\n<p>O di\u00e2metro do medidor de caudal eletromagn\u00e9tico deve corresponder ao di\u00e2metro do tubo para garantir um funcionamento adequado dentro da sua gama de caudal efetivo. Um medidor de caudal com um di\u00e2metro demasiado grande ou demasiado pequeno pode afetar a precis\u00e3o da medi\u00e7\u00e3o. Para aplica\u00e7\u00f5es de baixo caudal ou baixa velocidade, recomenda-se normalmente a sele\u00e7\u00e3o de um medidor de caudal com um di\u00e2metro ligeiramente mais pequeno para melhorar a sensibilidade e a precis\u00e3o.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9ca39f elementor-widget elementor-widget-menu-anchor\" data-id=\"f9ca39f\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"9\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d5b060a e-flex e-con-boxed e-con e-parent\" data-id=\"d5b060a\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e89d407 elementor-widget elementor-widget-text-editor\" data-id=\"e89d407\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<h4>3. Velocidade do fluxo e fluxo em escala real<\/h4>\n<p>A precis\u00e3o da medi\u00e7\u00e3o de um medidor de caudal eletromagn\u00e9tico permanece est\u00e1vel dentro de uma gama espec\u00edfica de velocidades de escoamento, normalmente de 1 a 10 m\/s para l\u00edquidos. Na pr\u00e1tica, velocidades de fluxo acima de 5 m\/s podem causar desgaste no revestimento do medidor de fluxo, especialmente se forem usados materiais mais macios como a borracha. Para aplica\u00e7\u00f5es de baixo caudal (abaixo de 1 m\/s), a redu\u00e7\u00e3o do di\u00e2metro do medidor de caudal pode ajudar a aumentar a velocidade do caudal e melhorar a intensidade e precis\u00e3o do sinal.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9ffbbd0 e-flex e-con-boxed e-con e-parent\" data-id=\"9ffbbd0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f564fc5 elementor-widget elementor-widget-image\" data-id=\"f564fc5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/medidores-de-caudal-magneticos\/\" target=\"_blank\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1011\" height=\"1024\" src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1011x1024.png\" class=\"attachment-large size-large wp-image-23402\" alt=\"Especifica\u00e7\u00f5es do medidor de caudal eletromagn\u00e9tico\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1011x1024.png 1011w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-296x300.png 296w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-768x778.png 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-340x344.png 340w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1516x1536.png 1516w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1000x1013.png 1000w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-100x100.png 100w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-46x46.png 46w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications-1300x1317.png 1300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flow-meter-specifications.png 1776w\" sizes=\"(max-width: 1011px) 100vw, 1011px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-ffa1d76 e-flex e-con-boxed e-con e-parent\" data-id=\"ffa1d76\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9adde8b elementor-widget elementor-widget-menu-anchor\" data-id=\"9adde8b\" data-element_type=\"widget\" data-widget_type=\"menu-anchor.default\">\n\t\t\t\t\t\t\t<div class=\"elementor-menu-anchor\" id=\"10\"><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-016abcb elementor-widget elementor-widget-heading\" data-id=\"016abcb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Escolher o n\u00edvel de precis\u00e3o correto<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a3864f5 e-flex e-con-boxed e-con e-parent\" data-id=\"a3864f5\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6afadd8 elementor-widget elementor-widget-text-editor\" data-id=\"6afadd8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>O n\u00edvel de precis\u00e3o do medidor de caudal eletromagn\u00e9tico \u00e9 crucial para a precis\u00e3o das medi\u00e7\u00f5es. A sele\u00e7\u00e3o do n\u00edvel de precis\u00e3o adequado com base nos requisitos espec\u00edficos ajuda a evitar custos desnecess\u00e1rios.<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Medidores de caudal electromagn\u00e9ticos de alta precis\u00e3o:<\/strong><\/span> Tipicamente, estes caudal\u00edmetros t\u00eam uma gama de erros de \u00b10,2% a \u00b10,5% e s\u00e3o adequados para aplica\u00e7\u00f5es que requerem medi\u00e7\u00f5es altamente precisas, tais como medi\u00e7\u00e3o e outros ambientes que exigem precis\u00e3o.<\/p>\n<p><span style=\"text-decoration: underline;\"><strong>Medidores de caudal electromagn\u00e9ticos de precis\u00e3o standard<\/strong><\/span>: Estes caudal\u00edmetros t\u00eam normalmente uma gama de erros de \u00b11% a \u00b12% FS e s\u00e3o adequados para aplica\u00e7\u00f5es industriais gerais. Oferecem uma boa rela\u00e7\u00e3o qualidade\/pre\u00e7o, satisfazendo a maioria dos requisitos operacionais.<\/p>\n<p>Ao selecionar o n\u00edvel de precis\u00e3o, considere as necessidades espec\u00edficas e o or\u00e7amento. Se n\u00e3o for essencial uma elevada precis\u00e3o, optar por um caudal\u00edmetro de precis\u00e3o normalizada pode ajudar a minimizar custos desnecess\u00e1rios.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-af614c3 e-flex e-con-boxed e-con e-parent\" data-id=\"af614c3\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-38ec947 elementor-widget elementor-widget-image\" data-id=\"38ec947\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"1001\" height=\"526\" src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1.png\" class=\"attachment-large size-large wp-image-25117\" alt=\"Imagem do procedimento de calibra\u00e7\u00e3o de um medidor de caudal eletromagn\u00e9tico.\" srcset=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1.png 1001w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1-300x158.png 300w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1-768x404.png 768w, https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/11\/Electromagnetic-flowmeter-Calibration-1300x68411-1-340x179.png 340w\" sizes=\"(max-width: 1001px) 100vw, 1001px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d98bae1 e-flex e-con-boxed e-con e-parent\" data-id=\"d98bae1\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-df9703d elementor-widget elementor-widget-text-editor\" data-id=\"df9703d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Fonte: <a href=\"https:\/\/automationforum.co\/calibration-procedure-for-electromagnetic-flowmeter\/\" target=\"_blank\" rel=\"noopener\">automationforum.co<\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a49d2af e-flex e-con-boxed e-con e-parent\" data-id=\"a49d2af\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d582098 elementor-widget elementor-widget-heading\" data-id=\"d582098\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Magnetic Flow Meter Installation and Troubleshooting<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-316c0ac e-flex e-con-boxed e-con e-parent\" data-id=\"316c0ac\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f127cfa elementor-widget elementor-widget-text-editor\" data-id=\"f127cfa\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li><a href=\"https:\/\/metlaninst.com\/pt\/que-precaucoes-devem-ser-tomadas-quando-se-utiliza-um-medidor-de-caudal-eletromagnetico\/\">Que precau\u00e7\u00f5es devem ser tomadas quando se utiliza um medidor de caudal eletromagn\u00e9tico?<\/a><\/li>\n<li><a href=\"https:\/\/metlaninst.com\/pt\/quais-sao-as-consideracoes-ambientais-e-de-instalacao-de-um-caudalimetro-magnetico\/\">Quais s\u00e3o as considera\u00e7\u00f5es ambientais e de instala\u00e7\u00e3o de um caudal\u00edmetro magn\u00e9tico?<\/a><\/li>\n<li>\u00a0<a href=\"https:\/\/metlaninst.com\/pt\/resolucao-de-problemas-de-caudalimetros-electromagneticos-impacto-dos-contaminantes-gasosos-e-solidos-estudos-de-caso\/\"><span class=\"current\">Troubleshooting Electromagnetic Flowmeters: Impact of Gas and Solid Contaminants<\/span><\/a><\/li>\n<li><a href=\"https:\/\/metlaninst.com\/pt\/resolucao-de-problemas-de-caudalimetros-electromagneticos-devido-a-alteracoes-nas-condicoes-de-fluxo\/\">Resolu\u00e7\u00e3o de problemas de medidores de caudal electromagn\u00e9ticos devido a altera\u00e7\u00f5es nas condi\u00e7\u00f5es de caudal<\/a><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-0acc2dc e-flex e-con-boxed e-con e-parent\" data-id=\"0acc2dc\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2354447 elementor-widget elementor-widget-heading\" data-id=\"2354447\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclus\u00e3o<\/h2>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b12ff37 e-flex e-con-boxed e-con e-parent\" data-id=\"b12ff37\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b16190c elementor-widget elementor-widget-text-editor\" data-id=\"b16190c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>A sele\u00e7\u00e3o do medidor de caudal eletromagn\u00e9tico adequado requer uma an\u00e1lise cuidadosa de v\u00e1rios factores, incluindo as carater\u00edsticas do meio medido, as gamas de temperatura e press\u00e3o de funcionamento, a velocidade do caudal e a correspond\u00eancia da gama de caudal, bem como a precis\u00e3o necess\u00e1ria. Ao fazer uma sele\u00e7\u00e3o informada, pode garantir o elevado desempenho, a efici\u00eancia e a fiabilidade a longo prazo do medidor de caudal eletromagn\u00e9tico. Este guia foi concebido para o ajudar a escolher cientificamente e com precis\u00e3o o medidor de caudal eletromagn\u00e9tico adequado \u00e0s suas necessidades.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1f7442b e-flex e-con-boxed e-con e-parent\" data-id=\"1f7442b\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3e1ac86 elementor-widget elementor-widget-heading\" data-id=\"3e1ac86\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Medidores de caudal magn\u00e9ticos<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6c27ffe elementor-widget elementor-widget-ts-products\" data-id=\"6c27ffe\" data-element_type=\"widget\" data-widget_type=\"ts-products.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"ts-product-wrapper ts-shortcode ts-product woocommerce columns-4 best_selling title-default product-default\" >\n\t\t\n\t\t\t\t\t\t\n\t\t\t<div class=\"content-wrapper\">\n\t\t\t\t<div class=\"products\"><section class=\"product type-product post-23218 status-publish first instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23218\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/p\/caudalimetro-eletromagnetico-flangeado-mtf-f-100\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-F-100-Flanged-Electromagnetic-Flow-Meter.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidor de caudal eletromagn\u00e9tico com flange MTF-F-100\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23218\"><span class=\"ts-tooltip button-tooltip\">Visualiza\u00e7\u00e3o r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23218\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23218\" data-product_sku=\"MTF-F-100\" aria-label=\"Adiciona ao carrinho: \u201cFlanged Electromagnetic Flow Meter (MTF-F-100)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cFlanged Electromagnetic Flow Meter (MTF-F-100)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/pt\/p\/caudalimetro-eletromagnetico-flangeado-mtf-f-100\/\">Medidor de caudal eletromagn\u00e9tico com flange (MTF-F-100)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23218\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23218\" data-product_sku=\"MTF-F-100\" aria-label=\"Adiciona ao carrinho: \u201cFlanged Electromagnetic Flow Meter (MTF-F-100)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cFlanged Electromagnetic Flow Meter (MTF-F-100)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23226 status-publish instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23226\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/p\/caudalimetro-magnetico-alimentado-por-bateria-mtf-b\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-B-Battery-Powered-Magnetic-Flowmeter.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidor de caudal magn\u00e9tico alimentado por bateria MTF-B\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23226\"><span class=\"ts-tooltip button-tooltip\">Visualiza\u00e7\u00e3o r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23226\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23226\" data-product_sku=\"MTF-B\" aria-label=\"Adiciona ao carrinho: \u201cBattery Powered Magnetic Flowmeter (MTF-B)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cBattery Powered Magnetic Flowmeter (MTF-B)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/pt\/p\/caudalimetro-magnetico-alimentado-por-bateria-mtf-b\/\">Medidor de caudal magn\u00e9tico alimentado por bateria (MTF-B)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23226\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23226\" data-product_sku=\"MTF-B\" aria-label=\"Adiciona ao carrinho: \u201cBattery Powered Magnetic Flowmeter (MTF-B)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cBattery Powered Magnetic Flowmeter (MTF-B)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23230 status-publish instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23230\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/p\/caudalimetros-magneticos-de-insercao-mtf-i\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-I-Insertion-Magnetic-Flow-Meters-600x600.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidores de caudal magn\u00e9ticos de inser\u00e7\u00e3o MTF-I\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23230\"><span class=\"ts-tooltip button-tooltip\">Visualiza\u00e7\u00e3o r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23230\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23230\" data-product_sku=\"MTF-I\" aria-label=\"Adiciona ao carrinho: \u201cInsertion Magnetic Flow Meters (MTF-I)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cInsertion Magnetic Flow Meters (MTF-I)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/pt\/p\/caudalimetros-magneticos-de-insercao-mtf-i\/\">Medidores de caudal magn\u00e9ticos de inser\u00e7\u00e3o (MTF-I)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23230\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23230\" data-product_sku=\"MTF-I\" aria-label=\"Adiciona ao carrinho: \u201cInsertion Magnetic Flow Meters (MTF-I)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cInsertion Magnetic Flow Meters (MTF-I)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23234 status-publish last instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23234\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/p\/medidor-de-caudal-eletromagnetico-para-liquidos-de-baixa-condutividade-mtf-c\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-C-Electromagnetic-Flowmeter-for-Low-Conductivity-Liquids.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidor de Caudal Eletromagn\u00e9tico MTF-C para L\u00edquidos de Baixa Condutividade\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23234\"><span class=\"ts-tooltip button-tooltip\">Visualiza\u00e7\u00e3o r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23234\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23234\" data-product_sku=\"MTF-C\" aria-label=\"Adiciona ao carrinho: \u201cElectromagnetic Flowmeter for Low Conductivity Liquids (MTF-C)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cElectromagnetic Flowmeter for Low Conductivity Liquids (MTF-C)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/pt\/p\/medidor-de-caudal-eletromagnetico-para-liquidos-de-baixa-condutividade-mtf-c\/\">Medidor de Caudal Eletromagn\u00e9tico para L\u00edquidos de Baixa Condutividade (MTF-C)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23234\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23234\" data-product_sku=\"MTF-C\" aria-label=\"Adiciona ao carrinho: \u201cElectromagnetic Flowmeter for Low Conductivity Liquids (MTF-C)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cElectromagnetic Flowmeter for Low Conductivity Liquids (MTF-C)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-22729 status-publish first instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters product_cat-water-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"22729\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/p\/caudalimetro-magnetico-para-agua-e-aguas-residuais-mtf-w\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-W-Magnetic-Flow-Meter-for-Water-and-Wastewater.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidor de caudal magn\u00e9tico MTF-W para \u00e1gua e \u00e1guas residuais\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"22729\"><span class=\"ts-tooltip button-tooltip\">Visualiza\u00e7\u00e3o r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=22729\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"22729\" data-product_sku=\"MTF-W\" aria-label=\"Adiciona ao carrinho: \u201cMagnetic Flow Meter for Water and Wastewater (MTF-W)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cMagnetic Flow Meter for Water and Wastewater (MTF-W)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/pt\/p\/caudalimetro-magnetico-para-agua-e-aguas-residuais-mtf-w\/\">Medidor de caudal magn\u00e9tico para \u00e1gua e \u00e1guas residuais (MTF-W)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=22729\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"22729\" data-product_sku=\"MTF-W\" aria-label=\"Adiciona ao carrinho: \u201cMagnetic Flow Meter for Water and Wastewater (MTF-W)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cMagnetic Flow Meter for Water and Wastewater (MTF-W)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23193 status-publish instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23193\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/p\/medidor-de-caudal-eletromagnetico-para-lamas-mtf-s\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-S-Electromagnetic-Flow-Meter-for-Slurry-600x600.jpg\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidor de caudal eletromagn\u00e9tico MTF-S para lamas\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23193\"><span class=\"ts-tooltip button-tooltip\">Visualiza\u00e7\u00e3o r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23193\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23193\" data-product_sku=\"MTF-S\" aria-label=\"Adiciona ao carrinho: \u201cElectromagnetic Flow Meter for Slurry (MTF-S)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cElectromagnetic Flow Meter for Slurry (MTF-S)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/pt\/p\/medidor-de-caudal-eletromagnetico-para-lamas-mtf-s\/\">Medidor de caudal eletromagn\u00e9tico para lamas (MTF-S)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23193\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23193\" data-product_sku=\"MTF-S\" aria-label=\"Adiciona ao carrinho: \u201cElectromagnetic Flow Meter for Slurry (MTF-S)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cElectromagnetic Flow Meter for Slurry (MTF-S)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23196 status-publish instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23196\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/p\/medidores-de-caudal-magneticos-sanitarios-mtf-a\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-A-Sanitary-Magnetic-Flow-Meters.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidores de caudal magn\u00e9ticos sanit\u00e1rios MTF-A\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23196\"><span class=\"ts-tooltip button-tooltip\">Visualiza\u00e7\u00e3o r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23196\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23196\" data-product_sku=\"MTF-A\" aria-label=\"Adiciona ao carrinho: \u201cSanitary Magnetic Flow Meters (MTF-A)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cSanitary Magnetic Flow Meters (MTF-A)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/pt\/p\/medidores-de-caudal-magneticos-sanitarios-mtf-a\/\">Medidores de caudal magn\u00e9ticos sanit\u00e1rios (MTF-A)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23196\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23196\" data-product_sku=\"MTF-A\" aria-label=\"Adiciona ao carrinho: \u201cSanitary Magnetic Flow Meters (MTF-A)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cSanitary Magnetic Flow Meters (MTF-A)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><section class=\"product type-product post-23199 status-publish last instock product_cat-magnetic-flow-meters product_cat-liquid-flow-meters has-post-thumbnail shipping-taxable purchasable product-type-simple\" data-product_id=\"23199\">\n\t<div class=\"product-wrapper\">\n\t\t\t\n\t\t<div class=\"thumbnail-wrapper\">\n\t\t\t<a href=\"https:\/\/metlaninst.com\/pt\/p\/medidor-de-caudal-magnetico-para-meios-de-alta-temperatura-mtf-h\/\">\n\n\t\t\t\t<figure class=\"no-back-image\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.metlaninst.com\/wp-content\/themes\/loobek\/images\/prod_loading.gif\" data-src=\"https:\/\/metlaninst.com\/wp-content\/uploads\/2024\/10\/MTF-H-Magnetic-Flow-Meter-for-High-Temperature-Medium.png\" class=\"attachment-shop_catalog wp-post-image ts-lazy-load\" alt=\"Medidor de caudal magn\u00e9tico MTF-H para meios de alta temperatura\" width=\"600\" height=\"600\" \/><\/figure>\n\t\t\t<\/a>\n\t\t\t\t\t<div class=\"product-label\">\n\t\t<\/div>\n\t<div class=\"product-group-button\"><div class=\"button-in quickshop\"><a class=\"quickshop\" href=\"#\" data-product_id=\"23199\"><span class=\"ts-tooltip button-tooltip\">Visualiza\u00e7\u00e3o r\u00e1pida<\/span><\/a><\/div><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23199\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23199\" data-product_sku=\"MTF-H\" aria-label=\"Adiciona ao carrinho: \u201cMagnetic Flow Meter for High Temperature Medium (MTF-H)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cMagnetic Flow Meter for High Temperature Medium (MTF-H)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t\t\n\t\t<\/div>\n\t\t<div class=\"meta-wrapper\">\n\t\t\t<h3 class=\"heading-title product-name\"><a href=\"https:\/\/metlaninst.com\/pt\/p\/medidor-de-caudal-magnetico-para-meios-de-alta-temperatura-mtf-h\/\">Medidor de caudal magn\u00e9tico para meios de alta temperatura (MTF-H)<\/a><\/h3><div class=\"product-group-button-meta\"><div class=\"loop-add-to-cart\"><a href=\"?add-to-cart=23199\" data-quantity=\"1\" class=\"button product_type_simple add_to_cart_button ajax_add_to_cart\" data-product_id=\"23199\" data-product_sku=\"MTF-H\" aria-label=\"Adiciona ao carrinho: \u201cMagnetic Flow Meter for High Temperature Medium (MTF-H)\u201d\" rel=\"nofollow\" data-success_message=\"\u201cMagnetic Flow Meter for High Temperature Medium (MTF-H)\u201d foi adicionado ao seu carrinho\" data-no-translation-aria-label=\"\" data-no-translation-data-success_message=\"\"><span class=\"ts-tooltip button-tooltip\" data-no-translation=\"\" data-trp-gettext=\"\">Adicionar<\/span><\/a><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/section><\/div>\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Os medidores de caudal electromagn\u00e9ticos s\u00e3o amplamente utilizados em aplica\u00e7\u00f5es industriais para medi\u00e7\u00e3o de caudal, particularmente em l\u00edquidos sem part\u00edculas s\u00f3lidas. A sua precis\u00e3o e fiabilidade s\u00e3o cruciais em muitas ind\u00fastrias. A sele\u00e7\u00e3o do medidor de caudal eletromagn\u00e9tico adequado envolve a considera\u00e7\u00e3o de v\u00e1rios factores relacionados com as condi\u00e7\u00f5es de funcionamento e as carater\u00edsticas do meio medido. Seguem-se algumas considera\u00e7\u00f5es fundamentais para o ajudar a [...]<\/p>","protected":false},"author":1,"featured_media":23423,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[124,123],"tags":[174,176,125,126,175],"class_list":["post-23383","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-magnetic-flow-meters","category-flow-meters","tag-electromagnetic-flow-measurement","tag-electromagnetic-flowmeter-principles","tag-flow-meters","tag-magnetic-flow-meters","tag-magnetic-flow-sensors"],"_links":{"self":[{"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/posts\/23383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/comments?post=23383"}],"version-history":[{"count":58,"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/posts\/23383\/revisions"}],"predecessor-version":[{"id":27239,"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/posts\/23383\/revisions\/27239"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/media\/23423"}],"wp:attachment":[{"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/media?parent=23383"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/categories?post=23383"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/metlaninst.com\/pt\/wp-json\/wp\/v2\/tags?post=23383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}