Magnetisch-induktiver Durchflussmesser für Flüssigkeiten mit niedriger Leitfähigkeit (MTF-C)

Produkt-CodeMTF-C
MTF-C is an electromagnetic flowmeter for measuring very low conductivity liquids (≥3 μS/cm). This flow meter is particularly suitable for applications with adhesive and greasy media that tend to form an insulating film.
Genauigkeit

Standard: ±1 %, Optional: ±0.5 %

Messbereich

1 m³/h to 125000 m³/h

Mittlerer Temperaturbereich

PU:0 to 140°F (-18 to 60°C)
Neoprene:-13°F to 176°F (-25°C to +80°C)
IR:-13°F to 176°F (-25°C to +80°C)
FEP:-13 to 300°F (-25 to 150°C)
PTFE:-13 to 300°F (-25 to 150°C)
ETFE:-40 to 356°F (-40 to 180°C)
PFA:-40 to 356°F (-40 to 180°C)

Max. Prozessdruck

40 bar (580.15 psi)

Benetzte Materialien

Liner: Polyuretane (PU), Neoprene, Isoprene Rubber (IR), Polytetrafluoroethylene (PTFE), Perfluoroalkoxy alkane (PFA), Ethylene tetrafluoroethylene (ETFE),Fluorinated Ethylene Propylene (FEP)
Electrodes: 316L Stainless Steel, Hastelloy, Platinum,Tantalum, Titanium, Tungsten carbide coated (Others on request)

Angebot anfordern

Beschreibung

Merkmale:

  1. Available for low conductivity liquids ≥3 μS/cm
  2. Wide range of liners and electrode materials
  3. Farben und Aussehen können nach Wunsch angepasst werden
  4. Auch in kundenspezifischen Konstruktionen erhältlich
  5. No moving parts, no wear, no pressure loss
  6. Reliable measurement at constant accuracy
  7. The measuring principle is virtually independent of pressure, density, temperature and viscosity
  8. Für die LCD-Anzeige stehen Englisch, Spanisch, Französisch und auf Anfrage weitere Sprachen zur Verfügung.
  9. Jeder Durchflussmesser wird kalibriert und erhält eine eindeutige Seriennummer, die alle Kalibrierdaten enthält.

Anwendungen:

Allgemein
    • Advanced applications with low conductivity media (≥3 μS/cm)
    • Aggressive and abrasive media
Chemische und andere Prozessindustrien
    • Precise volumetric dosing of additives
    • Corrosive, abrasive liquids and slurries
    • Dosing of adhesives and fibrous products
    • Emulsions incl. latex, emulsion paints etc.
    • (Bio-)alcohols, spirits, glycols, glycerine
    • Organic mass production
    • Oil based products
Lebensmittel- und Getränkeindustrie
    • Hygienic blending, dosing and batching
    • Fatty and oily products (e.g. vegetable oils)
    • Creamy and dairy products (e.g. fat, cream, milk, cheese, yoghurt with fruit particles)
Minerals and mining industry
    • Inhomogeneous and abrasive fluids
    • Cement and similar applications
Wasser- und Abwasserwirtschaft
    • Sludge and sewage
    • Water mixed with fat, oil and grease (e.g. in anaerobic co-digestion)
    • Irrigation
Zellstoff- und Papierindustrie
  • Chemically aggressive fibrous products
  • Products that form a film insulating the electrodes (waterglass)

Spezifikationen

Produkt-Code

MTF-C

Nenndurchmesserbereich

DN 25 to 3000 (1" to 120")

Benetzte Materialien

Liner: Polyuretane (PU), Neoprene, Isoprene Rubber (IR), Polytetrafluoroethylene (PTFE), Perfluoroalkoxy alkane (PFA), Ethylene tetrafluoroethylene (ETFE),Fluorinated Ethylene Propylene (FEP)
Electrodes: 316L Stainless Steel, Hastelloy, Platinum,Tantalum, Titanium, Tungsten carbide coated (Others on request)

Genauigkeit

Standard: ±1 %, Optional: ±0.5 %

Reproduzierbarkeit

Standard: Max. ±0.33 %, Optional: Max. ±0.16 %

Messbereich

1 m³/h to 125000 m³/h

Max. Prozessdruck

40 bar (580.15 psi)

Mittlerer Temperaturbereich

PU:0 to 140°F (-18 to 60°C)
Neoprene:-13°F to 176°F (-25°C to +80°C)
IR:-13°F to 176°F (-25°C to +80°C)
FEP:-13 to 300°F (-25 to 150°C)
PTFE:-13 to 300°F (-25 to 150°C)
ETFE:-40 to 356°F (-40 to 180°C)
PFA:-40 to 356°F (-40 to 180°C)

Umgebungstemperaturbereich

-25ºC ~ 60ºC

Ausgänge

4-20 mA, Frequency, Pulse

Digitale Kommunikation

RS485 (HART and others on request)

Stromversorgung

DC 24 V
AC 100 to 240 V

Medium Electrical Conducitvity

≥3μs/cm

Prozess-Verbindungen

Geflanscht (andere auf Anfrage)

Grad des Schutzes

IP65, IP66, IP67, IP68 (optional)