Débitmètres massiques à effet Coriolis pour applications cryogéniques (MASS-C)

Code produitMASS-C
MASS-C is the standard high performance Coriolis mass flowmeter for the process industry, which is the optimum device for cryogenic media like Liquefied Natural Gas (LNG) with temperatures down to -200°C / -328°F.
Précision

Standard: ±0.5 %, Optional: ±0.2 %; ±0.15 %

Plage de mesure

0-70 kg/min (0-154 lb/min)

Gamme de température moyenne

-328 to 185°F (-200 to 85°C)

Pression max. Pression de traitement

40 bar (580.15 psi)

Measuring tube

Austenitic stainless steel (316L), Hastelloy C, and others on request

Demande de devis

Description

Caractéristiques :

  1. Designed for cryogenic melia like LNG with temperatures down to -200°C / -328°F
  2. Suitable for use in Safety Instrumented Systems
  3. High accuracy mass, density and volume flow measurement
  4. Également disponible dans des constructions spécifiques au client
  5. L'anglais, l'espagnol, le français et d'autres langues sur demande sont disponibles pour l'affichage LCD.
  6. Chaque débitmètre est étalonné et reçoit un numéro de série unique correspondant à toutes les données d'étalonnage.

Applications :

    Général
  • Cryogenic temperatures down to -200°C / -328°F
  • Super critical gases
  • Custody transfer (CT)
  • Safety Instrumented Systems
  • Industrie chimique et autres industries de transformation
  • Concentration and density measurement
  • Bulk loading
  • Batching and blending to reactors
  • Hydrocarbon cracking
  • Industrie pétrolière et gazière
  • Metering skids, bulk loading, pipeline transfer
  • Liquefied Natural Gas (LNG)
  • Bulk loading
  • Multiphase measurement in upstream applications
  • Industrie alimentaire et des boissons
  • Batching, dosing, filling
  • Mass flow measurement of ice cream and milk
  • Measurement of flow, density, specific gravity in brewing processes
  • Dosing of hop extract
  • Measurement of Brix, density and flow in fruit juices
  • Dosing of natural oils, grease, vegetables (e.g. spinach) etc.
  • CO2 injection in soft drink production
  • Pharmaceutical industry
  • Batching, dosing, filling
  • Solvent extraction
  • Marine industry
  • Bunkering and fuel consumption measurement
  • Industrie du papier et de la pâte à papier
  • Additives, bleaches and colourants
  • Crystallising, solidifying and cryogenic products

Spécifications

Code produit

MASS-C

Gamme de diamètres nominaux

DN04 (1/6”), DN08 (1/4”), DN15 (1/2”)

Measuring tube

Austenitic stainless steel (316L), Hastelloy C, and others on request

Précision

Standard: ±0.5 %, Optional: ±0.2 %; ±0.15 %

Répétabilité

Standard: Max. ±0.25 %, Optional: Max. ±0.1 %; ±0.075 %

Plage de mesure

0-70 kg/min (0-154 lb/min)

Pression max. Pression de traitement

40 bar (580.15 psi)

Gamme de température moyenne

-328 to 185°F (-200 to 85°C)

Plage de température ambiante

-40 to 131°F (-40 to 55°C)

Sorties

4-20 mA, Impulsion

Communication numérique

Modbus/RS-485 (HART et autres sur demande)

Alimentation électrique

DC 15 to 40 V
AC 15 to 30 V

Connexions de processus

Flanged, Female thread, Sanitary connection(Others on request)

Degré de protection

IP67

Retour en haut de la page
fr_FRFrançais